jablotron JA-62GSM Скачать руководство пользователя страница 2

The JA-62GSM communicator for GSM 

The JA-62GSM communicator for GSM 

2 / 11 

MLD52902 

Example

 by sending: “SET code” (SET space valid code) the system will set 

(if it is already set it will not change its status) 

Notes: 

 

the access code is always required for the commands SET and UNSET  

 

the system will 

confirm performance of the SMS

  instruction by an 

SMS reply, if this function is enabled 

 

the SMS instruction texts are not case-sensitive and only ASCII 

characters are allowed 

 

the SMS instruction texts can contain multiple instructions separated with 

a comma 

 

if you are sending an instruction and you are not sure whether any other 

text will be automatically added to the SMS on the way (for example, 

when using an SMS internet gate) type the instruction as: 

%instruction code %%

  

 

the valid code can also be entered automatically, see 6.6. 

4.  User communicator programming 

User setting of the communicator is performed by entering sequences from 

the Profi system keypad. Selected parameters can also be controlled or set 

by SMS instructions. 

Setting on the system keypad is possible only in the case that the control 

panel is in 

maintenance mode

  (if it is not, enter F0 master code when 

system is unset – Factory default setting 1234). Modification of values set in 

the communicator is performed by entering programmable sequences (see 

Tab. 7). 

Press the # button to exit Maintenance mode

 or to cancel code entering 

when you enter a wrong number. 

If setting of telephone numbers in Maintenance mode is enabled in the 

control panel settings (sequence 251 of the Profi  control panel), then it is 

possible to set the following communicator parameters in Maintenance mode 

by keying in the below mentioned sequences beginning with 8: 

  Set telephone numbers M1 to M8 

  Select events which should be reported by an SMS message and calling  

  Measure GSM signal strength  

  Limit the number of sent SMSes 

  Record voice messages 

4.1. Setting of telephone numbers for reporting  

The communicator reports events in the Profi  system by sending a text 

SMS and / or calling and transmitting a voice message. Reporting can be 

programmed for to up to 8 telephone numbers.  

The most frequently desired reports are already assigned to the telephone 

number memories by factory-default, so you only need to program tel. 

numbers to the particular memories: 

 

Overview of reports assigned to tel. numbers (this can be modified see 6.4) 

Reports 

Alarms by SMS and phone call, faults by SMS 

  

 

 

   

    

 

 

 

Alarms by SMS and phone call 

Alarms by SMS and phone call 

Alarms by SMS 

Alarms by SMS and phone call 

Alarms by SMS and phone call 

Alarms by SMS 

Technical faults by SMS (for a service technician) 

tab. 2 Reports assigned to telephone number memories M1to M8 

To program phone numbers to the M memories, enter the following 

sequence while in Maintenance / Service mode: 

81 M  xxx...x F0 

where: 

M

 

is memory number 1 to 8 

 

xxx...x

  is a telephone number (max. 20 digits) 

 

To erase a number from memory M enter: 

81 M F0 

 

Example:

 entering 

81 5 777 777 777 F0

 will store the number 777777777 in 

memory M5 (alarms will be reported by SMSes + phone calls with a voice 

message). 

Notes: 

 

In a split system, when you change a detector’s section, adjust the 

reaction of the detector etc, you have to enter enrollment mode for 1 s 

and leave it before you leave service mode. This way the changes are 

saved in the communicator. 

 

Entering  F9 before the first digit will insert a “+” for the international 

formatting of phone numbers. 

 

SMS report text consists of the installation name, event type, name of the 

event source, date and time. For example: “Report from your alarm: 

setting 47: device Time 11:27 01.08 ”. 

 

If other events or texts should be reported to a particular number, change 

the communicator settings (see 6.4, 6.7  and tab.  5  the list  of events 

which can be reported to your phone and their factory default settings). 

5.  Voice menu for control via a telephone  

The communicator is equipped with voice navigation for remote control of 

the basic system functions (remote access via a telephone must be enabled). 

The menu has factory default voice reports in multiple languages –  the 

desired languages is selected by entering the 

991 xx

 sequence (see 6.1). 

The voice navigation is as follows: 

 

 

After 15 seconds of ringing the communicator will answer the call and 

require entering the valid code. 

 

After entering a  valid code  for remote access  the  system reports its 

current status (always 1x) and opens the keypad simulation mode and 

allows entering the controlling / programming sequences. 

 

When you enter a  valid access code, the  system is set / unset and 

confirms the system status. For an incorrect entry the system generates 

a series of beeping sounds. 

 

When you enter programming sequences, a correct entry is confirmed 

by one beep, an incorrect entry is rejected and indicated by a series of 

beeps. 

 

When the system is in the service / maintenance mode, code verification 

is performed and if the code is valid, you will hear: “Service mode, 

keypad simulation“. 

 

By entering the sequence 892, you enter the voice message recording 

mode. 

6.  Installation programming 

The most convenient and complete programming is best done by a PC 

running Comlink software and higher connected locally at the installation or 

remotely via the Internet.  

The communicator can also be programmed by keying in sequences from 

the system keypad or via SMS programming instructions. 

Programming by the system keypad is possible only if the control panel is 

in 

Service mode,

 if it is not, key in *0 Service code (factory default setting: 

6060) with the alarm system unset (disarmed) The setting is performed by 

keying in programming sequences, (see Tab. 7 communicator programming 

sequences). 

Press the # button to exit service mode

 or to cancel code 

entering when you key in a wrong number. 

6.1. Communicator language setting 

The language of the texts and voice menu used by the communicator can 

be set by the instruction:  

991 xx 

where: 

xx 

is a number defining the language – see the following 

list: 

 

01 

EN 

English 

08 

IT 

Italian 

02 

CZ 

Czech 

09 

PT  Portuguese 

04 

NL 

Dutch 

10 

FI 

Finnish 

05 

DE 

German 

12 

SV  Swedish 

06 

PL 

Polish 

14 

HU  Hungarian 

07 

DA 

Danish 

15 

RU  Russian 

 

 

Example: Keying in 99101 will set English. 
Notes: 

 

entering 00 will reset the texts and voice messages to the factory default 

values in the currently set language. 

 

set the language before editing the text in the system (a change of 

language will change the text to the factory default setting) 

 

The set language will not change when a reset is performed 

Factory default setting:

 

99101 = English

 

6.2. GSM signal strength measuring 

A good quality GSM signal is necessary for the reliable functioning of the 

communicator. Enter the 

888

 to start GSM signal strength measuring. The 

keypad then displays the signal strength in the range 0  to  9  and the 

measuring is repeated every second – new data is indicated by a beep. This 

Содержание JA-62GSM

Страница 1: ...or directional GSM antenna see 6 2 GSM signal strength measuring 8 If the GSM signal strength is sufficient test the communicator functions system control via a mobile phone etc see the instructions...

Страница 2: ...ved in the communicator Entering F9 before the first digit will insert a for the international formatting of phone numbers SMS report text consists of the installation name event type name of the even...

Страница 3: ...e text string but a space is valid within the text string spaces outside the text string are ignored Notes A single SMS TXT instruction can modify multiple texts limited only by the maximum length of...

Страница 4: ...or this activity can be requested automatically with a preset cycle and if it finds out that the remaining credit is lower than the preset value an information SMS is sent The function is set by send...

Страница 5: ...SIM card requires them must be programmed by sending the following SMS instruction to the communicator code_GPRS_x x_y y_z z where Code valid service system code e g 0000 _ space x x SIM card APN y y...

Страница 6: ...tocol allows very frequent checking of ARC communication even every 5 minutes in practice When 00 00 is set a communication check is not performed Factory default setting 23 59 hours mins 7 7 Enable A...

Страница 7: ...grammed repeat period see 7 6 If an alarm is cancelled by a user while it is being reported any unsent SMSes and unperformed call reports are cancelled but the ARC still gets a complete set of reports...

Страница 8: ...7 other event 24 21 Receiver jamming 5 fault 30 22 Setting Two section system Armed system 31 23 Unsetting Two section system Disarmed system 30 24 Setting zone A Armed system 31 25 Setting zone B Ar...

Страница 9: ...mode 539 Partial unsetting B 23 Wireless detector 7 409 Discharged battery 540 Communicator failure 24 Wireless detector 8 410 Tamper alarm 541 Communicator OK 25 Wireless detector 9 411 Alarm memory...

Страница 10: ...o 4 codes key fobs and master code setting unsetting enabled Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first progr...

Страница 11: ...ording to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours mi...

Отзывы: