The JA-62GSM communicator for GSM
10 / 11
MLD52902
•
12. Communicator programming sequence overview
Sequences beginning with “8“ are also accessible from Maintenance mode if the change of telephone numbers in Maintenance mode is enabled
(Profi control panel sequence 251)
Function
Sequence
Possible options
Factory default settings
Communicator language setting
991 xx
xx=01-EN, 02-CZ, 04-NL, 15-RU
Language selection affects SMS texts and
basic voice navigation features
01-English
GSM signal strength measuring
888
range from 0 to 9, exit by pressing N
-
Tel. number programming for
reporting to telephones
81 M xx..x F0
M
= memory 1 to 8;
xx..x
= tel. number (max.20 digits)
entering F9 i, entering F7 inserts *,
81 M F0 erases the number in memory M
all M1 to M8 erased
Selection of events to report by SMS
82 M uu x
M
= tel. number memory 1 to 8
uu
= event code, see the List of events which
can be reported to your phone and their
x=0
no report
x=1
report
M1 alarms and faults by SMS.
M2 and M3 alarms by SMS and phone calls
M5 and M6 alarms by SMS and phone calls
M4 and M7 alarms SMS
M8 faults only by SMS from
Selection of events to report by
phone call
83 M uu x
See the List of events which can be reported
to your phone and their factory default
Codes associated with enrolled
telephones
84 M xxxx
If an SMS with no code arrives from
telephone number M, xxxx is used as a code
for identification, entering
84 M F0
erases the
given code
No code
SMS and instruction text editing
The texts can be changed by ComLink software or by sending an
instructional SMS:
code TXT n,text,n,text...
Voice message recording
The recording is performed via a mobile phone; the system must be in service or user mode. Dial the system SIM
card number from your telephone. When the system answers, enter the valid access code (0000) and then enter
892
from cell phone keypad. The communicator informs you that voice message recording mode entered, see the
installation manual.“ see 6.8
Enable reporting to phones
901 x
x=0 disabled
x=1 enabled (all programmed)
x=2 enabled
without reporting
setting/unsetting by users 1 to 4
(codes &
key-fobs) and master code setting / unsetting
enabled
Forwarding of incoming SMS
messages
801 x
x=0 no, x=1 if the incoming text is not an
SMS instruction it will be forwarded to the first
programmed number in memories M1 to M8
yes
SMS instruction confirmation
904 x
x=0 no, x=1 yes (by SMS reply)
yes
Reaction to incoming calls
905 x
x=0 no reaction
x=1 answers after 15s ringing
answers after ringing for 15s
GSM signal dropout indication
906 x
x=0 no, x=1 yes (15min. dropout =fault)
no
Phone speaker loudness
909 x
x=0..9, 0=minimum,9=maximum
5
Number to be called to maintain SIM
card validity
910 xx..xF0
xx..x = tel. number (max.20 digits), 910 F0
erase the number
Erased
Restriction of the number of sent
SMSes to max. 50 SMSes per 24
hours
803 x
1=restriction enabled, 0=restriction disabled
restriction enabled
SIM card credit interrogation
You can inquire about credit balance by sending the SMS instruction:
code CREDIT uu..u xx yyy zz
where code =
master or service code, uu..u = GSM network command string to ascertain the credit (e.g.
∗
104
#
), xx=auto-interrogation
frequency in days, yyy=minimum acceptable balance, zz= the textual position at which the number showing the balance
starts in the reply message from the GSM provider. If the credit is lower than the set minimum value, the provider’s SMS
will be auto-forwarded to numbers M1 and M8 for someone to top up the pre-paid SIM card
Programming by SMS
The system can be programmed remotely via SMS instruction
code PRG seq, seq,...
where seq are programming
sequences set in the same way as from the keypad (e.g.
0000 PRG F06060 201 N
sets a 10s exit delay
(a space in the sequence causes a 500ms pause)
Registration code
911 xx...x F0
xx..x = tel. number to which the registration
code should be sent
Re-registration to the GSM network
893
the communicator disconnects from the GSM network and then re-registers itself.
Communicator reset
998080
Resets to the factory default settings and erases all phone numbers, text will not be changed
SIM card’s PIN code
920 xx..x F0
xx..x = PIN, 920 F0 erases the PIN (to use a
SIM card with a disabled PIN)
erased
GPRS parameter settings
by SMS instruction:
code GPRS apn user pass
where apn = APN, user = username, pass = password (only enter the
APN if the name and password are not required by the GSM provider)
Tab. 7 communicator programming sequence