background image

The JA-62GSM communicator for GSM 

The JA-62GSM communicator for GSM 

1 / 11 

MLD52902 

The communicator is a component of the Jablotron JA-63K(R) Profi 

system. It has been designed for communication via a GSM network. It is 

installed directly within the control panel housing and it allows the following: 

  event reporting by SMS (for up to 8 telephone numbers) 

  event reporting by phone call with voice message warnings (it is possible 

to record up to 7 messages for various events)  

  remote control and programming by phone (by calling and using the 

voice navigation or by SMS instructions) 

  remote control of the system (or appliances in the house) 

  data transmission to an Alarm Receiving Centre (ARC) - up to 2 ARCs 

  remote programming of the ARC by internet application

 

 

It is not possible to register the communicator on www.gsmlink.cz 

The GSM communicator should be installed by a trained technician with a 

valid certificate issued by an authorised distributor. 

1.  Installation in the control panel 

If you purchased the communicator module separately, it should first be 

installed in the JA-63 Profi control panel as follows: 

a)  The control panel 

power must be switched o

ff (both mains and 

battery) 

b)  Fit the communicator inside the control panel housing using screws and 

connect its cable

 to the main board. 

c)  Attach the adhesive GSM antenna inside the control panel’s plastic 

housing (it can be glued in a suitable place) and connect the antenna to 

the communicator. 

Warning: never switch the control panel power 

on if the GSM antenna is not connected to the GSM module as 

this will cause serious damage!!!

 

 

Fig. 1 Communicator description: 

Description: 1. Red LED signalling connection to a GSM network; 

 2. Green LED signalling normal operating mode; 3. Control panel connector; 

4. GSM antenna connector; 5. SIM card 

2.  Initial powering up of the communicator 

The communicator is installed in the control panel and its GSM antenna is 

connected, then: 

1. 

Have a suitable SIM card ready

. It should be activated (see if it works  

in a mobile phone first). The SIM card should have the following services 

actived: SMS, data (GPRS), voice and CLIP (caller identification). If it 

requires a PIN code when switching the phone on, 

then disable the PIN 

code request upon the first use of the phone

); e.g.  Nokia: Menu / 

Settings / Security settings / PIN code request / Off, if the SIM card 

requires the PIN code enter it, see 6.17. The communicator can work 

with a prepaid card, but we recommend using a tariff card for more 

reliable functioning. 

2. 

Insert the SIM card

  into the communicator (to open the card holder 

push its frame up a little). 

3.  Switch on the control panel power (both mains and battery). The 

communicator’s red LED should be lit = registering to the GSM network; 

it should go off within a minute = registration successful.

 

4.   If the red LED starts flashing after a while, switch off the control panel 

power, put the SIM card into a mobile phone and check that it registers to 

the network in the place where the control panel is installed without any 

PIN code requests. 

5. 

Close the control panel cover

, the alarm system should be in Service 

mode - if it is not, enter F0 Service code (Factory default setting: 6060) 

with the alarm system unset (disarmed). 

6.  Key in 

99101

 - to set the 

texts

 and voice messages of the communicator 

to the English language.

 

7.  Enter 888 to measure the GSM signal strength (a number in the range 

from 0 to 9 should be displayed). It should be 

at least 3

 to ensure reliable 

functioning. If the signal is weak, change the location of the control panel 

or try a SIM card from another GSM provider (it is not recommended to 

use either a high-gain or directional GSM antenna – see 6.2 GSM signal 

strength measuring). 

8.  If the GSM signal strength is sufficient, test the communicator functions 

(system control via a mobile phone, etc), see the instructions below. 

Warning: If installed at a location near a national border where the 

signal strength fluctuates, roaming to a foreign network is highly likely. 

We therefore recommend blocking the roaming feature in the SIM card 

to avoid unnecessarily high communication fees (contact your GSM 

provider for details).

 

3.  User functions of the communicator 

The following text describes all communicator features. The installer should 

show the end user how to operate the functions used in the particular 

installation. 

3.1. Event reporting to the user’s phone  

The communicator reports events in the Profi  system by sending a text 

SMS and / or calling and transmitting a voice message. Reporting can be set 

to up to 8 telephone numbers. The most frequently used report variants are 

preset but they can be customized. 

Notes:  

 

If used, transmissions to the Alarm Receiving Centre have absolute 

transmission priority (see 7.4). 

 

Calling is usually used to draw the user’s attention to a detailed report 

sent in an SMS. If reporting by SMS is enabled, the communicator first 

sends all SMS messages before it starts dialling the set numbers.  

 

Message playing can be terminated by pressing #  on the telephone 

keypad. The keypad then switches into keypad simulation mode and the 

messages are not further transmitted to other numbers. 

3.2. Temporarily authorizing a phone as a system keypad 

It is possible to operate the system remotely by temporarily authorizing a 

phone keypad as follows: 

a)  dial the communicator’s SIM card number 

b)  after 15 seconds of ringing, the system will answer and ask for a code. 

c)  enter a valid control panel access code on the telephone keypad – the 

code assigned to the telephone (see chapter 6.6), or use a service code 

for remote access (default 0000) 

d)  once the code has been entered, the system tells you the current status 

and turns on the Keypad simulation mode 

e)  connection is terminated by hanging up the  call, if nothing is entered 

within a minute, the phone call will end automatically anyway 

f)  the maximum allowed phone call length is 30 minutes 

Notes: 

 

a land line phone can also be used to control the system remotely in the 

same way, a condition is that the phone must use tone dialling (DTMF) 

 

do not enter sequences on the phone too fast

, each key signal needs 

a certain time to be sent (it depends on the particular phone and the 

quality of the GSM connection 

 

Service code for remote access default is set to 0000 

3.3. SMS instructions to control the system remotely 

All incoming SMSes are checked by the communicator and if there are any 

instructions to the system, they will be performed. Each instruction message 

must have the following format: 

Instruction_code 

(i.e. valid code space instruction) 

SET 1234 

Valid code = any valid code in the system (e.g. 1234), saved in the control 

panel. 

The factory-default instruction texts (editable – see TXT command).  

Command 

Function 

Note 

SET 

setting 

(arming) 

setting or unsetting (the same way as if the 

used code is entered on the system 

keypad), If the system is already in the 

desired mode, it will not change 

UNSET 

unsetting 

(disarming) 

STATUS 

reports 

system status 

including GSM signal strength, GPRS 

connection and ARC communication 

(shown as MS1, MS2 and MS3) 

MEMORY 

reports latest 

events 

this concerns the last 3 events from the 

control panel memory 

PGON 

turns on PG 

the PG output has to be programmed for 

the function PHONE (enter sequnce 

238/248) 

PGOFF 

turns off PG 

CREDIT 

SIM card 

credit inquiry 

it has to be initialized before it can be used 

– see 6.17 

DINFO 

SMS info 

about device 

version 

SMS on assembly info: firmware, 

hardware and ve reg. key 

Tab. 1 SMS commands 

Содержание JA-62GSM

Страница 1: ...or directional GSM antenna see 6 2 GSM signal strength measuring 8 If the GSM signal strength is sufficient test the communicator functions system control via a mobile phone etc see the instructions...

Страница 2: ...ved in the communicator Entering F9 before the first digit will insert a for the international formatting of phone numbers SMS report text consists of the installation name event type name of the even...

Страница 3: ...e text string but a space is valid within the text string spaces outside the text string are ignored Notes A single SMS TXT instruction can modify multiple texts limited only by the maximum length of...

Страница 4: ...or this activity can be requested automatically with a preset cycle and if it finds out that the remaining credit is lower than the preset value an information SMS is sent The function is set by send...

Страница 5: ...SIM card requires them must be programmed by sending the following SMS instruction to the communicator code_GPRS_x x_y y_z z where Code valid service system code e g 0000 _ space x x SIM card APN y y...

Страница 6: ...tocol allows very frequent checking of ARC communication even every 5 minutes in practice When 00 00 is set a communication check is not performed Factory default setting 23 59 hours mins 7 7 Enable A...

Страница 7: ...grammed repeat period see 7 6 If an alarm is cancelled by a user while it is being reported any unsent SMSes and unperformed call reports are cancelled but the ARC still gets a complete set of reports...

Страница 8: ...7 other event 24 21 Receiver jamming 5 fault 30 22 Setting Two section system Armed system 31 23 Unsetting Two section system Disarmed system 30 24 Setting zone A Armed system 31 25 Setting zone B Ar...

Страница 9: ...mode 539 Partial unsetting B 23 Wireless detector 7 409 Discharged battery 540 Communicator failure 24 Wireless detector 8 410 Tamper alarm 541 Communicator OK 25 Wireless detector 9 411 Alarm memory...

Страница 10: ...o 4 codes key fobs and master code setting unsetting enabled Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first progr...

Страница 11: ...ording to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours mi...

Отзывы: