background image

JA-60V Wireless outdoor PIR detector 

2

 MEB 

52101 

Detection length setting table: 
 

Max. detection length 

Position 

Standard  

See Note bellow 

12 m 

10.0 to  15.0 m 

8 m 

  6.0 to  10.0 m 

5 m 

4.0 to  5.5 m 

2 m 

1.5  to  2.5m 

 
NOTE: the maximum detection length may vary as above due to 
environmental thermal condition.

 

Detection Area

Level  A,B,C,D

No Detection

Tolerance

 

 
Active area angle is 90°. By holding the pyro-electric unit it can be turned 
in to desired direction ( in 15° steps).  

45

90

45

 

 

Area masking – 

by provided

 

masking plates section of the detection area, 

which is exposed to the reflection of the sunlight, car light etc. can be 
masked. 
  

Sensitivity of the PIR sensor can be set by “SENS” switch in three 
steps:   

 

L  - 

low 

M - 

 middle   

H -

  high    

 

Other parameters can be set using a DIP switch:  

 

 

       LED indicator OFF

 

LED indicator ON

 

 120 

s

 

5 s Battery saving timer

 

 

4x 

2x Pulse count

 

 

 

LED indicator is to be used for testing of the PIR detector. During 
normal operation period is recommended to switch it off to save the 
battery.  
Depending on the 120s/5s battery saving timer DIP switch the movement 
sensor will be blocked for a period of 5 or 120 seconds after a movement is 
detected to conserves battery energy. 
Depending on the Pulse count DIP switch the detector (both upper & 
lower detection area) must be triggered 2 or 4 times to transmit the 
alarm signal. 

 

Operation test  

 

Turn the LED indicator on, set the “battery saving timer” to 5 seconds 
and close the detector. Every 5 seconds any movement in the 
detection area will be indicated by the LED indicator and the alarm 
information will be sent to the control panel.  

 

Operation 

 

To increase batteries lifetime it is highly recommended to switch the 
“battery saving timer” to 120 seconds and switch off the LED indicator 
in normal operating mode. The movement sensor will be blocked for 5 or 
120 seconds after a movement is detected. This means that if there is 
constant movement in the detection area the detector will transmit 
information about the movement only once every 5 or 120 seconds.  

 
 
 

Battery testing and replacement 

 

The detector automatically checks the condition of its batteries. If it is 
necessary to replace the batteries, the detector will inform the control panel 
about it. If a low battery is indicated the detector works as normal but, 
batteries should be replaced as soon as possible (within a week). 

Before replacing the batteries, the control panel must be switched into 

mode, which allows detectors opening (

U

ser mode or 

P

rogramming 

mode).  
Use only high quality alkaline AAA batteries for replacement.  

Note: Dispose of batteries safely depending on the type of the batteries and 
local regulation. Although this product does not contain any harmful materials 
we suggest you to return the product to the dealer or directly to the producer 
after usage. 

 

Troubleshooting 

 
Problem Probable 

cause 

Remedy 

Lower detection area is 
unnecessarily long 

Set the detection area 
properly 

Detector receives 
reflection of the reflector, 
sunlight, car light etc. 

Remove the reflector, 
mask the area exposed to 
the reflection of light or 
change position of the 
detector 

There is a heat source in 
the area that can cause 
fast temperature change 
(stove, heater etc.) 

Remove the source of 
heat or change position of 
the detector 

Detector 
makes false 
alarms 

There is any moving object 
in the area (laundry on the 
clothesline, plans etc.) 

Remove the moving object 
or change position of the 
detector 

Detection area is not set 
properly 

Set the detection are 
properly 

Occasionally 
no detection  Sensitivity is set to low (L) 

Change sensitivity to 
medium (M) or high (H) 

Low battery 

Replace the battery 

LED does not light 

Turn LED switch ON 

Detector 
fails to work 

LED indicator lights but no 
reaction on the control 
panel 

The control panel is out of 
range, check the battery, 
try to replace detector or 
control panel 

 

 

 
 

80

198

108

 

Dimensions 

 
 

Note:

 Although this product does not contain any harmful    

materials we suggest you to return the product to   the dealer 

or directly to the producer after usage. 

 

 
 

 

 
 
 

Internet: www.jablotron.cz

Tel.:  483 559 999  
fax:  483 559 993

Pod Skalkou 33 
466 01 Jablonec nad Nisou