JA-60GSM communicator module
- 10 -
MFJ51212
7.4
Events to be reported to CMS
There are 31 types of events, which can be reported to each CMS –
see table 7.4.1. This sequence sets which events should be reported
to CMSs.
05 p uu y
where
p
1 = CMS1, 2 = CMS2
uu
events index – see table 7.4.1
y
0 = report disabled, 1 = report enabled
Default setting: all reports are disabled
7.4.1
Table – complete list of events to be reported to CSM
Events index uu
Events description
01
Intruder alarm – instant zone
02
Intruder alarm – delayed zone
03
Fire
alarm
04
Panic alarm
05
Wrong access code alarm
06
Alarm after power on
07
Tamper alarm
08
Tamper OK
09
Alarm
end
10
Alarm canceled by a user
11
Arming
12
Disarming
13
Partial arming (Home)
14
No code arming
15
External communication failure
16
External communication recovery
17
Failure
18
Failure recovery
19
AC failure longer than 30 minutes
20
AC failure
21
AC recovery
22
Battery failure
23
Battery recovery
24
Enter programming mode
25
Exit programming mode
26
Remote access
27
Remote access – end
28
RF jamming
29
Internal communication failure
30
Internal communication recovery
31
Periodic test
7.5
CMS re-dialing pause setting
If the dialer is activated it attempts to make a connection (alternating
between the primary and the backup telephone number). If it is not
possible to make a connection, a pause is initiated. After this pause
the dialer will attempt again. The pause length can be set in the
following way:
06 p t
where
t
pause duration
x 5 minutes (1 = 5 minutes, 2 = 10
min,..., 9 = 45 minutes)
p
1 = CMS1, 2 = CMS2
Default setting: 5 minutes for both CMSs
7.6
Interval of periodic test
The periodic test for checking the CMS link is set by activating event
No 31. The following sequence sets the time length from the last
reported event to the moment when the periodic test report should be
transferred.
07 p hhmm
where
p
1 = CMS1, 2 = CMS2
hh
hours
mm
minutes
Default setting: The periodic test report is sent 24 hours after the last
reported event.
7.7
Disabling CMS communication
If you need to disable all CMS reports temporarily, you can do this,
while retaining your settings:
0 0 p 0
all
reports to CMS
p
disabled
0 0 p 1
all reports to CMS
p
enabled
Default setting:
all CMS reports disabled.
7.8
CMS 2 as a back up for CMS1
CMS 2 can serve as an optional back-up for CMS if data transfer to
CMS1 fails. When the first event is transferred to the backup
monitoring station (CMS2) an event “tel. line #1 communication fault“
will be reported.
080
CMS1 and CMS2 are two independent stations
081
CMS 2 works as a back up for CMS 1.
When 081 is selected, CMS 2’s settings are used only in the case of
CMS 1 transfer failure.
Default setting
: two independent CMSs.
7.9 Storing the event “data to CMS sent” into the event memory
By this sequence it is possible to disable recording of the event that
indicates that data to a CMS has been sent to the list of event in the
control panel.
Programming sequences:
090
The CMS data transfer event is not recorded
091
The CMS data transfer event is recorded
Default setting
:
The CMS data transfer event is recorded
8
The modem function
The GSM communicator can also be used as an external modem for
accessing the Internet (GPRS format). It is necessary to have GPRS
activated in the SIM card and to have a connection cable connected to the
COM port of the PC. Support for MS Windows operating systems can be
found on the enclosed CD. The modem can only be used when all CMS
reports, SMSs and system calls have been executed.
When the modem is used:
It is possible to use the attached telephone, the internet connection will
be temporally suspended
Received SMSs are stored and they will be processed after modem
disconnection
The modem will be disconnected if an alarm or an arming event occurs
9 Additional
information
9.1
Priorities for event reporting:
If the dialer is activated to send an event report it will:
send information to CMS1 (trying primary and back up
numbers twice) if programmed
send information to CMS2 (trying primary and back up
numbers) if programmed
send SMS reports (1
st
telephone number, 2
nd
telephone
number,…. 8
th
tel. number)
send audible reports (1
st
telephone number, 2
nd
telephone
number,…. 8
th
tel. number) – each number is only called
once, whether it is answered or not
if the attempt to send a report to a CMS has not been
successful, the dialer will try to resend it after the re-dialing
pause (sequence 06px). The dialer will make three attempts
at sending event reports to a CMS, i.e. it will wait (according
to the setting 06px) twice for the re-dial pause. Only a new
event will result in an additional attempt to call the CMS.
If any event is triggered which should be reported to a CMS while the
alarm system is being remotely accessed by phone, the report will be
sent after remote access has finished.
If a user cancels an alarm, all reports, which have not been sent yet,
will be deleted, except for CMS reports.
9.2
The LED on the dialer PCB
•
LED flashing means the dialer has not entered the GSM network
•
LED flashing (3x) – the communicator (modem) is controlled by a PC.
•
LED being on means– communication with a GSM network
−
connecting to the GSM network
−
the dialer is calling
−
the dialer is sending an SMS
9.3
Entering programming mode
•
The dialer will finish the current CMS connection (the attached
phone will ring shortly to confirm this)
•
The current audible warning is interrupted immediately
•
SMSs and audible warnings, which remain unsent before entering
programming mode, are erased – they will not be sent after exiting
programming mode