background image

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

JA-163A RB Wireless outdoor battery-powered siren

JA-163A RB Wireless outdoor battery-powered siren

1 / 2

MNM51103

The JA-163A RB is a component of the 

JABLOTRON 100

system.

It is used for system alarm indication outside a building. It can also be used 
for supplementary acoustic signalling (PG activation, arming, chirps). 
The siren is powered by just one lithium battery with no other external 
power. The JA-163A RB includes only the base with the 

JA-163A-BASE-

RB

PCB, the BAT-100A lithium battery and always has to be completed 

with a cover from the 

JA-1X1A-C-xx

series (see following table). The siren 

occupies one position in the system. The product should be installed by 
a trained technician with a valid certificate issued by an authorized 
distributor.

For combinations of colour and cover material, see the following table:

Cover type

Colour and cover 

material

Strobe colour

JA-1X1A-C-GR

Grey plastic

Red

JA-1X1A-C-ST

Stainless steel sheet

JA-1X1A-C-WH

White plastic

JA-1X1A-C-GR-B

Grey plastic

blue

JA-1X1A-C-ST-B

Stainless steel sheet

JA-1X1A-C-WH-B

White plastic

Installation

The whole enrolment procedure has to be done in service mode 

of the control panel. There must be a JA-11xR radio module installed 
in the control panel.

Figure 1: 1 – hole for installing; 2 – piezo sounders; 3 – BAT-100 lithium battery 

with reusable battery strap (up to 2 batteries can be used); 4 – PCB;

5 – spirit level; 6 – hole for installation with tamper detection; 7 – front cover 

screw; 8 – string with clip connecting the front cover for easy installation

The siren should be installed on a vertical 
wall, with the flasher facing downwards. 
Avoid installing the siren near the gutters and 
on other places where there is a danger of ice 
accumulation.

1.

Attach the siren onto a suitable place using 2 screws through 
the holes (1) and (6). The spirit level can be used for easy 
installation (5). 

2.

Connect the BAT-100A lithium battery (3) to the connector (11).

3.

Proceed according to the control panel installation manual.
Basic procedure:

a.

When the battery is connected, the yellow LED (12) indicates 
by a permanent light that the siren has not been enrolled into 
the system yet.

b.

Go to the 

F-Link

software, select the required position 

in the 

Devices

tab and launch the enrolment mode by clicking on 

the 

Enroll

option.

c.

Press the button marked LEARN (10) – the siren is thus enrolled 
and the yellow LED indicator goes off.

4.

Put back the siren cover and attach it using the screw (7).

5.

Perform siren properties setting, see the following chapter: Internal 
settings of the siren.

Notes:

The siren can also be enrolled into the system by entering 
its production code (9) in the F-Link software. You can find 
the production code on the sticker, glued on the PCB. 
All numbers under the bar code shall be entered (1400-00-0000-
0001).

The siren can be powered by up to two BAT-100A batteries and we 
recommend this when longer siren operation time is required. 
There is a place prepared for second battery use see Figure 1. 
Connect the battery to the other connector (11). The battery connection 
order doesn´t matter.

Figure 2: 9 – production code; 10 – LEARN (enrollment) button; 

11 – battery connector; 12 – yellow fault indicator; 13 – mini USB connector; 

14 - piezo siren connection (attention: high voltage); 

15 – external antenna connector; 16 - high intensity red LED flashers

Erasing the siren from system / RESET

Use this procedure when the siren has to be erased from one system 

and enrolled to another one. Proceed this way:
1. The control panel has to be in 

Service

mode.

2. Open the siren cover and disconnect the BAT-100A battery from 

its connector.

3. Go to the F-Link software, 

„Devices“ tab,

and erase the siren from 

the control panel and 

leave service mode

.

4. Connect the BAT-100A battery. Then press and hold the LEARN 

button (10) for approximately 8 sec until the yellow LED (12) starts 
flashing. Then release the button.

5. When flashing expires (2 x 7 flashes) the yellow LED illuminates.

This indicates that the siren is not enrolled.

Notes:

-

When a reset is done the yellow LED goes off and it means that 
there is some control panel in the siren’s radio range with 
an open service mode and the enrollment procedure has been 
performed again and the siren is assigned to that control panel.

FW update

1. A FW update can be performed by the F-Link software in service 

mode, but only by a user with 

Service

authorisation.

2. Start the F-Link software and enter service mode.
3. Open the siren cover.
4. Do not disconnect the battery!
5. Connect a PC to the siren using a mini USB cable.
6. FW update mode is indicated by the flickering of the yellow LED.
7. Continue as with updating the control panel using F-Link software; 

F-

/LQN&RQWUROSDQHOĺ8SGDWHILUPZDUH

. In the device options 

select the USB option (typically at the first position).

8. Press the 

OK

button to perform an update of the selected device.

9. Disconnect the mini USB cable.
10. Close the siren cover.
11. Check the siren settings via 

F-Link SW, Devices / Internal 

settings

.

12.

Test the siren functions.

Notes:

A mini USB cable is not in the supplied accessories of the siren, control 
panel or any other device. You can use the cable from 
the JA-190T card reader. We strongly recommend connecting 
the USB cable straight to the PC connection as using a USB HUB can 
reduce the reliability.

According to the changes which have been done during the update, 
previous settings might stay or settings could be erased to default. 
When a reset has been done you can reload the previous settings

by the Import button and restore them with no negative influence 

on the new firmware.

Internal settings of the siren

The siren properties can be set in the 

Devices

window of the F-Link 

software. When at the siren position, use the 

Internal settings

option 