JABLOTRON
ALARMS
a.s.
Pod
Skalkou
4567/33
46601
Jablonec
n.
Nisou
Czech
Republic
www
.jablotron.com
||
|
JA-155E, JA-155E-GR, JA-155E-AN Wireless four-segment keypad with
display and RFID reader
Typ: 5KPAD2202LU
JA-155E, JA-155E-GR, JA-155E-AN
3 / 3
MLU510701
Periodical communication with CP once every 8 s
– Enabling
the parameter to extend the battery lifetime. However, this setting
will increase the response time of the keypad in response to system
states (entry and exit delay, alarms, segment status change).
Delayed panic
–
this function triggers a panic alarm (silent or loud)
with an adjustable delay during which the alarm can be cancelled.
Activation and deactivation are done by a segment button configured
to Silent panic or Audible panic. Pressing the red segment button
(right) starts the timing and pressing the green segment button
cancels the timing. When authorization is enabled then it is required
for activation and deactivation. The delay is adjustable from 1 to 255
seconds.
Keypad light intensity in DAY / NIGHT mode.
Segment
– segment button light intensity setting
Keypad
– numeric keypad backlight setting
Display
–
LCD backlight setting
*Mute
– in the NIGHT mode, the keypad will be without
any acoustic indication. It will not indicate exit
delay, alarm, key press, etc. In the DAY mode,
it will indicate according to the setting "Acoustic
indication of selected sections“
*
- the option is available only in NIGHT mode
A keypad configuration which complies with
certification requirements must be selected
from the list of System profiles in the
Parameters tab of the F-Link SW.
Date and time
– the current date and time is automatically
displayed on the bottom line of the LCD display (2) of the keypad if
this segment is without function.
Temperature
– displays the measured temperature of the selected
detector on the bottom line of the LCD display (2) of the keypad if
this segment is without function.
Import
– the import button allows you to copy keypad settings to
another keypad in the system of the same type. This can be used,
for example, if an object has multiple entrances and it is necessary
to set all keypads in the same way. The Import button provides
a history of the last keypad settings at a given device position. This
function can also be used when replacing a faulty keypad with a new
one.
Keypad FW update
1. Updates can only be done by a Service technician with the
F-Link SW.
2. Start the F-Link SW and open the appropriate database.
3. Enter the service mode
4. In a toolbar click to:
Control panel
→
Update firmware
5. In the devices menu table, select the required device; if
Automatic Update is disabled, select the FW package file
(included in the F-Link installation or can be published for
download separately, file type *.fwp).
6. Press
OK
to upgrade the selected device.
7. When the update is complete, check the keypad setting in the
F-Link, Devices / Internal settings
. Depending on the changes
made during the update, the previous settings of the module may
be retained or reset to factory defaults. If a reset has been
performed, the
Import
button can be used to select from the
previous settings and restore them without breaking the new
firmware.
Technical specifications
Power supply
4 x alkaline batteries, type: AA (LR6) 1.5 V
Please note: Batteries are not included.
Typical lifetime of batteries
1–2 Years
LowBatt state
<4.5 V
Quiescent current consumption (6 V)
245 μA
Maximum current consumption (6 V)
115 mA
External power supply 12 V +/-1 V
typ. 45 mA, max. 100 mA
Maximum cable length
3 m
Communication band
868.1 MHz, JABLOTRON protocol
Maximum radio-frequency power (ERP)
<25 mW
Communication range
approx 200 m (open area)
RFID frequency
125 kHz
Maximum RFID magnetic field strength
-
5.4 dBμA/m
(measured at 10 m)
Dimensions
110 x 136 x 33 mm
Weight (w/o batteries)
285 g
Classification
Security grade 2/Environmental class II (according to EN 50131-1)
Environment
indoor general
Operating temperature range
-10 °C to +40 °C
Average operating humidity
75% RH, w/o condensation
Certification body
Trezor Test s.r.o. (no. 3025)
In compliance with
ETSI EN 300 220-1,-2, ETSI EN 300 330,
EN 50130-4, EN 55032, EN 62368-1,
EN 50131-1, EN 50131-3, EN 50131-5-3, EN 50131-6,
Operating conditions according to general authorization
ERC REC 70-03
Recommended screw
4 x
ø 3.5 x 40 mm (half-round head)
JABLOTRON ALARMS a.s. hereby declares that the
1KPAD2201LU is in a compliance with the relevant
Union harmonisation legislation: Directives No:
2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/EU.
The original of the conformity assessment can be
found at www.jablotron.com – Section Downloads
Note:
Disposing of this product correctly will help save
valuable resources and prevent any potential negative
effects on human health and the environment, which
could otherwise arise from inappropriate waste
handling. Please return the product to the dealer or
contact your local authority for further details of your
nearest designated collection point.