jablotron JA-155E Скачать руководство пользователя страница 1

JABLOTRON

ALARMS

a.s.

Pod

Skalkou

4567/33

46601

Jablonec

n.

Nisou

Czech

Republic

www

.jablotron.com

||

|

JA-155E, JA-155E-GR, JA-155E-AN Wireless four-segment keypad with 

display and RFID reader 

Typ: 5KPAD2202LU 

JA-155E, JA-155E-GR, JA-155E-AN 

1 / 3 

MLU510701 

The keypad is a wireless component of the 

JABLOTRON 

system. 

It serves for the controlling and displaying system status indication. 

It is equipped with four segments; their descriptions are displayed on 

the LCD display. The device should be installed by a trained 

technician with a valid certificate issued by an authorized distributor. 

The keypad is compatible with following control panels 

JA-102K, JA-103K and JA-107K. 

It is necessary to use this manual in combination with the 

JABLOTRON 100 installation and user manuals. 

The keypad comprises of 4 segments (1), LCD display (2), keypad 

and RFID card/tag reader (4). 

Figure 2: 6 – battery holder; 

7 – serial number; 8 – tamper 

contacts; 9 – locking mechanism 

Figure 1: 1 – control buttons; 2 – LCD display; 3 – system indicator / button;  

4 – keypad with RFID reader; 5 – cover;

  

Figure 3: 9 – locking mechanism; 10 – tab 

Figure 4

: 11 – terminals of an external power supply and an external 

magnetic contact 

Installation 

1. Remove the mounting pad (rear part) of the keypad. If you can´t

remove it easily, open the locking mechanism, see paragraph

Alternative power supply

 and 

Installation of a magnetic contact

2. Mount the back of the keypad to a  flat wall using 4 screws.

To connect an external power supply or magnetic contact, use

the terminals on the back of the keypad, see Figure 4.

 

See the

connection description in the paragraphs the Alternative Power

Supply and Installation of a magnetic contact.

3. For enrolling to the system, the JA-11xR radio module must be

installed in the system.

4. Insert 4x 1.5V AA alkaline batteries into the keypad, mind the

correct polarity!

5. Enrollment to the system according to the type of control panel

use the recommended software or application, see the

installation manual of the control panel.

6. First attach the bottom edge of the keypad to the mounting pad (rear 

part) of housing (align the bottom sides). Then slide the keypad

downwards, until you hear the click of the tab (10). This will secure 

the keypad against falling out of the installation pad. Then turn the

locking mechanism (9) clockwise 90° to the position where the

groove points to the   symbol). This locks the keypad in place and 

engages the tamper contact. 

Notes: 

Enrollment is also possible by entering its serial number (7) in

the F-Link software or using a bar code scanner. All numbers

stated under the bar code must be entered (1400-00-0000-

0001).

The tilting cover (5) can be removed if the user prefers permanent

access. 

Keypad disassembly 

On the underside of the keypad, turn the locking mechanism (9)

 

anticlockwise 90° until the groove points to the symbol  . Then use 

a screwdriver to release the tab (10) while sliding the keypad up. The 

keypad can then be easily removed from the mounting pad. (If the 

mounting pad is not screwed on, use the same procedure, just slide 

the mounting pad downwards against the keypad).

 

Setting the properties 

The settings are configured by the F-Link software - 

Devices

 tab. 

Use the 

Internal settings

 option on the device position. A dialogue 

window will appear in which all the keypad functions can be set. The 

internal settings are divided  into two basic tabs: 

Segments

  and 

Settings

The Segments tab:

 

Within the 

Segments

  tab, the required functions can be set for 

individual segments (control of sections, indication of section status, 

triggering of a panic alarm, control of PG output, indication of PG 

output status, etc.). 

The segment descriptions can be edited in  F-Link directly by 

clicking on the segment text. 

Authorization

 – setting and unsetting requires user authorization. 

When this parameter is disabled,  the segment can be operated 

without authorization. By disabling the parameter, the specific 

segment can be controlled without authorization, except for the 

Unset section function, for which authorization is always required. 

When switching PG outputs on and off, the Authorization / No 

Authorization function is enabled for both states. 

Common segment 

– settings and description of function 

One of the other functions of the segment is called Common 

segment (max 1 common segment can be set per keypad). This 

simulates the simultaneous pressing of several segments controlling 

sections located on this keypad. The selection of sections assigned 

to a common segment is done via F-Link  - 

Devices 

tab, at the 

module position select 

Internal Settings

Segments

 tab and select 

the function called 

Common segment A

 by selecting the segment. 

The overview of segments that will be controlled at once is visible in 

the newly displayed 

Common Segment

 tab. 

If the status of the segments controlled by the 

Common segment

 

is different, the remaining segments will be set/unset after its use. 

If one of the selected segments has the Partial setting function 

enabled, then the Common Segment respects this setting: 1st press 

of the Set button = partial setting, 2nd press of the Set button = full 

setting. 

The Common segment function should not be combined with the 

Section / Common section function. 

Common segment indications: 

Green

  = all sections are unset fully 

Yellow

  = sections are in various states or all of them are 

set partially 

Red

 

= all sections are set fully 

In the 

Settings

  tab, you can adjust the remaining keypad 

parameters such as acoustic indication, backlight intensity, RFID 

reader function, optical indication and display settings. Details of the 

settings can also be found in the F-Link SW mouseover help bubble. 

Automatic stand-by mode 

When the keypad is powered from batteries, it saves energy and 

turns off system optical indication, backlight and RFID reader after 8 

seconds without pressing a key or closing the keypad cover. 

However, the keypad also maintains communication with the control 

panel and can indicate, for example, entry delay. The keypad will be 

completely active when the keypad cover is opened or pressed, or 

any button or segment pressed. 

Отзывы: