The JA-152A wireless internal siren for an AC socket 

The JA-152A Wireless internal siren to an AC socket 

1 / 2 

MNJ21000 

The JA-152A is  a wireless device of the 

JABLOTRON 100

  system.  

It is used for alarm indication inside a building with an option  

to distinguish the alarm type according to the type of signalling. It can 

also be used for other acoustic indication (PG outputs, entry/exit delays, 

doorbell). Pressing the siren can silence an  alarm (= confirmation  

of a person’s presence in the building) or trigger a panic alarm (optional 

function). The siren is equipped with a backup battery for cases of AC 

dropouts. It has also got a built-in tamper sensor for the  detection  

of disconnection from an electrical socket. The siren takes one position 

in the system and it should be installed by a trained technician with  

a valid certificate issued by an authorized distributor. 

 

Figure 1: 1 – transparent control button 

Installation and enrollment to the system 

When enrolling the siren to the system, the system has to be  

in service mode and equipped with a JA-11xR radio module. The battery 

is already connected as default. 
1.  Plug the siren into the required electrical  socket  within RF range  

of the control panel. The control button (1) lights with a yellow colour 

indicating that the siren is ready to be enrolled. 

2.  Proceed by following the control panel installation manual.  

Basic instructions: 
a.  Open the 

F-Link

  software, select the  required position  

in the 

Devices

  tab and click on the 

Enroll 

button to enter the 

Enrollment mode

b.  Press the control button (1).  The yellow LED goes off and  

the siren is enrolled to the required position.  

c.  Set the siren properties (see the Internal settings chapter). 

Warning

:  

In case of unplugging the siren from the electricity, the siren  

is powered by the backup battery and is able to work for at least 24 hrs. 

When the backup battery voltage reaches critical level, the battery  

is disconnected to protect it against damage; the siren is out of service 

from this moment. 

Internal settings of the siren 

Go to the 

Devices

  tab in the 

F-Link

  software. When you are  

at the siren position, use the 

Internal settings

 option to open a dialog 

window where you can set: 

(* indicates default settings)

The setting tab: 

Tamper detection

with its built-in accelerometer the siren detects its 

removal from the electrical  socket. Options 

DISABLED,  ALWAYS*, 

DURING ALARM. 

Acoustic indication from  sections: 

determines  for which sections 

the siren should indicate an alarm. The default is indication for  all 

sections. 

Reaction: 

defines whether the siren should indicate an 

IW*

 (internal 

warning) or an 

EW

 (external warning) signal. Alarm indication with this 

siren can also be completely disabled (other functions remain active). 

Siren sound: 

intermittent*, continuous.

 

Maximum siren time: 

1, 2, 3*, 4, 5

 minutes

 

and

 OFF

 – if the OFF 

option is selected the acoustic indication corresponds to  the 

Alarm 

length

 parameter in the 

Parameters

 tab in the 

F-Link

 software 

Different fire alarm indication: 

YES/NO* 

–  determines whether  

the siren will differentiate between acoustic indications of fire and 

standard alarms. The acoustic indication of a fire alarm is identical  

to smoke detectors with an internal siren – fast beeping. 

Other acoustic indication from sections: 

determines for which 

sections the siren will  indicate other types of alarm.  The default  

is indication for all sections. 

When controlled by a section: 

YES/NO* 

–  if enabled, the siren 

beeps 1x after setting, 2x after unsetting and 3x when unsetting after  

an alarm. Valid only for the selected sections. 

During warning:

 YES/NO* 

–  if enabled, the siren reacts with three 

beeps to the inability to set the system, unsuccessful setting and 

unsetting with an active alarm memory. 

Entry delay: 

YES/NO*

 

– if enabled, the siren indicates the entrance 

delays of the selected sections. 

Exit delay when partially set: 

YES/NO* 

–  if enabled, the siren 

indicates the exit delays of the selected sections when the system  

is partially set. This option is available only when the exit delay of fully 

set sections is enabled. 

Exit delay when fully set: 

YES/NO*

 – if enabled, the siren indicates 

the exit delays of the fully set selected sections. 

Level of volume of supplementary acoustic indication:

 

Standard*, Increased, By button, Programmable 

–  Applies only  

to other acoustic indication and the acoustic indication of PG outputs.  

It has no influence on the volume of alarm indication. If the “By button” 

option is selected, the volume can be changed by a user by pressing  

the  button  for 3 seconds (when the system is out of service mode) –  

the change of volume is confirmed by a beep and in the volume  

of the new selected volume. The “Programmable” option displays a time 

slider  which sets  a period of time to switch between the standard and 

increased loudness during the day. 

The Signalling PG tab: 

LED indicates sounding PG output: 

If enabled, an  acoustic 

indication triggered by an active PG output is continuously indicated by 

LED.

 

Sound indication can be set for each PG output:

 

Slow beeping 

–  beeps 1x per second (as long as the PG output  

is active) 

Quick beeping

 – beeps 2x per second (as long as the PG output  

is active) 

1x ON / 2x OFF

 – beeps 1x when the PG output is activated, beeps 

2x when the PG output is deactivated 

20 s of beeping

 – beeps continuously for 20 s when a PG output  

is activated. 

Melodies 1 to 4

 – four available doorbell melodies. 

Test 

 

by pressing the Test button you can test the siren function.  

The siren responds with 3 s alarm sound.

  

System reaction to pressing the siren 

button 

The default setting is that pressing the siren button during an alarm 

mutes the siren and at the same time confirms a person’s presence  

in the building (a report is  sent). In the 

Devices

  tab in the 

F-Link

 

software 

Reaction

  option,  you can change the siren button reaction  

to  another function, for example a  panic alarm. In such a case  

the system responds to the pressing with a panic alarm in the section  

to which the siren has been assigned. 

Setting to comply with security grade 2 

If this setting is required, use the 

F-Link

  software, 

Parameters

  tab, 

System profiles

  option. There you can choose the  required security 

profile (EN 50131-1, gr. 2). The siren will be configured accordingly. 

Siren signalling priorities 

The highest priority is given to a fire alarm indication, followed by IW 

and EW alarm indication. Control indication has a lower priority and PG 

output activation indication has the lowest priority. Indication with 

a higher priority always terminates an indication with a lower priority. 

The list of acoustic indication priorities in descending order:  

Fire alarm, IW and EW alarm, warning indication, unsetting the system 

with  an active alarm memory, setting/unsetting,  entrance, exit, alarm 

memory, PG output indication (PG1 has a higher priority than PG2 etc.) 

and lastly LED flashing when the status of tamper sensor changes. 

Backup battery replacement 

The siren checks the backup battery status automatically. The current 

status can be checked in the 

Diagnostics

  tab in the 

F-Link

  software, 

where the current battery status is displayed and also its voltage when 

loaded and unloaded. When a backup battery fault is triggered  

it is necessary to replace it as fast as possible to  avoid a complete 

malfunction of the siren in the case of an AC dropout. 