JA-151IR wireless 4beam optical barrier 

 

JA-151IR wireless 4beam optical barrier 

1 / 2 

MMY51902 

The JA-151IR four-beam infra-red optical barrier is designed for the indication of 

a breach into a protected area by crossing the IR line between the transmitter and 
the receiver. The barrier is a product by Optex supplemented with transmitters 
compatible with the JABLOTRON 100. The device is equipped with a 4-ray optical 
part with a high immunity against false alarms and the detection of small animals. 
The barrier occupies two positions in the system. The transmitters regularly 
perform automatic tests and report their status to the system. The barrier should 
be installed by a trained technician with a valid certificate issued by an authorised 
distributor.  

Barrier installation 

The following instructions should be observed when selecting a place for 

barrier installation: 

x

  Both units must be installed on a stationary construction (e.g. a wall or a 

thick post) at the same height and should face each other. 

x

  The area between the barrier units must not be blocked by any bushes 

or tall grass.  

x

  There can be up to a 100 m distance between the units indoors. (The 

distance could be reduced outdoors.) 

x

  The receiver unit must not be affected by direct sunlight. 

x

  The units should be installed 0.7 – 1 m above the ground.  

x

  If the IR beam is parallel to a wall, there must be at least a 1 m distance 

between the beam and the wall. 

x

  If multiple barriers are used, it is necessary to avoid influencing the 

beam of one barrier by another barrier 
 

 

Fig. 1 Undesirable locations 

 

 

Installation steps:  

The transmitting unit (marked TRANSMITTER) and the receiving unit 

(marked RECEIVER) are of identical mechanical construction. 

 

 

 

Fig. 2  Barrier parts (identical for transmitter and receiver): A – Front barrier 

cover, B – Main unit, C – Base of the unit, D – Rear cover, 1 – The locking 

screw of the front cover, 2 – Viewfinder for barrier alignment, 3 – Optical part, 

4 – Setting of optical viewing angle, 5 – Screws for main unit fixing,  

6 – Battery holders, 7 – Jablotron transmitter 

 

 

1.  Unscrew the front cover screw (1) and remove it. Use a coin inserted 

between the thresholds of the plastic parts to get it out and carefully take it 
off by a prying motion. 

2.  Take away the main unit with the base (B+C) by releasing the 4 screws (5) 

in the corner of the base unit (C). Then take the base of the unit away from 
the rear cover (D). 

3.  Install the rear cover (D) onto the selected place, either directly onto a wall or 

a post. On the rear plastic case holes are pre-pressed for installation on the 
wall (WALL) or for a pole (POLE).  

4.  The Jablotron transmitter (7) and battery holders (6) are placed inside the 

rear cover (D). Everything is connected to the main unit by a coloured wiring 
harness with connectors. The connectors are unmistakable.  

Enrolling the barrier transmitters into the 

system 

The radio transmitters for communication with the JABLOTRON 100 

system are placed inside the rear cover (D) underneath the optical part of the 
detector. The barrier occupies 2 positions in the system. Barrier activation is 
reported by the receiving part of the barrier. Both barrier parts report 
tampering and battery status. 

For powering each unit always use a minimum of two SAFT LSH20 

lithium batteries 

(they are included in the package). The correct position of 

the batteries is marked inside the holder. Mind the correct polarity during 
insertion. Four batteries can be inserted into the receiver and transmitter as 
well. This prolongs the barrier operational time.  

  

1. Enroll the radio transmitter to the system. 

a.  There must be a JA-110R radio module installed in the system. 
b.  Go to the 

F-Link

 software, select the required position in the 

Devices

 

window and launch the enrollment mode by clicking on the 

Enroll

 option. 

c.  Insert the batteries (mind the correct polarity). The enrollment signal is 

transmitted when the first battery is inserted into the detector and the 
device is enrolled to the selected position. 

2. Screw on the base (C) and main (B) unit. 
3.  Do the barrier optical alignment according to the following chapter.  
4. Screw on the cover and test the barrier functioning.  

 

                                                                Receiver 
 

 

                                                                 N.C.                      

N.O. 

 

 

Status (INP)

 Pulse 

(INP) 

 

AUX Fault

 AUX 

Antimasking

 

 

 

Not used                         

 

                                                                   Transmitter 

 

                                                                 N.C.                      

N.O. 

 

 

Status (INP)

 Pulse 

(INP) 

 AUX 

Fault 

AUX Antimasking

 

 

 

Not used                                  

                          

                                            

Factory settings highlighted by bold letters. 

 

Fig. 3 Fig. 3 Radio transmitter (matched transmitter and receiver): 

1 – terminals, 2 – option DIP switch (factory pre-set), 3 – external tamper 

connector, 4 – external antenna jumper, 5 – external antenna connector 

 

If needed the transmitter can be equipped with an AN-80 or AN-81 

external antenna connected to the connector (5) and disconnect the 
jumper (4).

 

Setting up the optical part of the barrier 

Always perform the detector settings and beam alignment when the 

tamper contact is blocked. The optical part of the barrier must be adjusted so 
that the optical parts facing each other are physically aligned. Both units are 
equipped with adjusting elements for the adjustment of direction and a view-
finder for precise adjustment. The unit opposite the one you want to adjust 
must be in the centre of the aiming cross and the cross must be in the centre 
of the view-finder (see fig. 4). There are optical covers placed inside the front 
barrier covers. Slide the cover on the lower optical part and perform the 
upper optical part setting then repeat the procedure for the lower part of the 
optics. If it is needed to test the barrier function with a closed front cover it is 
possible to lock the tamper contact by a rotating plate to avoid physical 
closing of the barrier. The rotating plate is placed next to the tamper contact.  

 

Fig. 4 Setting up the optical part 

 

12

3

4

ON

12

3

4

ON

Отзывы: