H-915  installation manual   

11/9 

TBT502 01 

y= 0 relay 

  1 ext. siren 
  2 panic 
  3 fire 
  4 arm 
  5 int. siren 

Note: If an output is activated by the [5][xy] command, the output will stay active until you press [

]. Then you are back 

in the installer programming level again. 
Example: Enter [5] [02] to activate the panic output, enter [

] to switch off this output. 

 
[8] Optional devices programming 

- for  programming of devices which are connected trough serial line. 

See corresponding device manual for more information when you install such a device. Press [#] to return to normal 
installer programming. 
 

[9] Events history output

. If you press [9] in the installer programming level the H-915 control panel will send 

information about events history to the special serial interface (printer) which can be connected to the keypad terminals 
as an option (the same function as in the User programming level [

][5]). 

 

Note

: Press [#] to return  to the standby level from the installer programming level when you finish programming. All  

programming is stored in the non voltage memory. Additionally, the current working mode is stored in the non voltage 
memory. If power is switched completely off, the control panel will return to the original settings when the power comes 
on again.  
For example, if the power is switched off completely and an alarm condition is present, the  control panel will start in the 
alarm condition when the power is switch on again. 
If there is any reason to switch the power completely off (for example when you want to extend the system with an 
optional device), we recommend  to enter the  installer programming level at first. 

 

FACTORY DEFAULT SETTING: 

 

Master Code

: 1234 

Installer Code

: 1010 

 

No other access codes programmed 

Zone definition

: 1 

delay 

 

2 next delay interior 

 

3 interior instant 

 4 

instant 

 5 

instant 

 6 

instant 

Timers

Exit delay: 40 sec. 

Entry delay: 

20 sec. 

Alarm duration: 

3 min. 

Alarm outputs

: Technical 

Relay 

only 

 

Fire  E.siren, I.siren, Relay, Fire 

 

Intruder  E.siren, I.siren, Relay 

 Panic 

Panic 

only 

Optional functions

Arming confirmed only by keypad's buzzer 

 

Loop 6 works as zone 6 input 

Number of attempts to enter code:  5 
 Quick 

arming: 

disabled 

 

Auto AT HOME arming:  disabled 

 

If somebody in:  alarm can be adible 

 
 

COMPLETE RESET: 

In the event that the master code or installer code is forgotten (or for some other reason), it is possible to completely 

reset all settings of the H-915 to the factory default. To do this, disconnect the power completely (A.C. and back up 
battery).  Then install the jumper RESET on the control panel board. 

Reconnect the power supply. Wait 2 seconds and remove the jumper. The control panel will perform a  self test and 

end  in installer programming mode (press [#] to entr stand by). 

 

WHEN INSTALLATION IS FINISHED: 

Explain and demonstrate all the functions of the H-915 system to the users. Be sure that they know how to program the 

access codes and how to operate the system. 

Содержание HESTIA H-915C

Страница 1: ...Security Alarm Control Panel HESTIA 915 installation manual ...

Страница 2: ...uired 12V from 1 2Ah to 40Ah stand by consumption 25mA back up power output 12V max 500mA inputs eight loops FIRE TAMPER and 6 fully programmable loops type of loops balanced with End Of Line resistor 10k remote control inputs digital bus for external keypads programmable optional pulse input outputs overswitching relay contact 1A at 60 V external siren output 0 5A at 12 V backup siren output BS f...

Страница 3: ...nput is also triggered if normally closed contacts wired in series with EOL resistor are opened see the wiring diagram The Fire alarm is activated if a detector connected to a FIRE input is triggered The Tamper alarm can be triggered either by the built in tamper switch control panel keypads or by the tamper switches connected to the TAMP input The definition of zone 1 to 6 delay instant 24hr fire...

Страница 4: ... 5 can be used connect all of them in parallel Check carefully that you have connected corresponding wires before you turn on the power to the control panel The built in keypad on the H 915C model is connected via INT KEY connector Control panel TAMPER There is a tamper switch to protect the housing of the control panel If you have only the H 915B main board don t forget to install the attached ta...

Страница 5: ...on was enabled in the installer programming level If quick arming is enabled the H 915 can be AT HOME armed by entering only the 9 command DISARMING Enter a valid access code to disarm If the chime jumper in the H 915K keypad is connected and you triggered a sensor in a delay zone the keypad buzzer will be beeping In such a case you have only a limited amount of time entrance delay to enter a vali...

Страница 6: ...atically in the moment when used once for arming NOTE If you press 9 in user programming level the H 915 control panel will send information about events history to the special serial interface printer which can be connected to the keypad terminals as an option Only code number 0 master code is programmed from factory the other access codes are blank 6 INSTALLER CODE Entering of INSTALLER PROGRAMM...

Страница 7: ...If the premises is entered without coming through a delay entrance and a next delay loop is triggered an immediate intruder alarm will be generated 05 24Hr silent loop operates as the type 01 but it triggers the PANIC alarm 06 Instant silent loop operates as the type 02 but it triggers the PANIC alarm 07 Delay silent loop operates as the type 03 but it triggers the PANIC alarm 08 Interior instant ...

Страница 8: ...rmed by both sirens The y can only be from 0 to 3 4 1y External arming control with loop 6 input If y 0 zone input 6 will work as programmed in section 1 If y 1 than zone input works as input for external arming and disarming If you close this input with E O L resistor for a moment it will have the same function as entering of a valid access code By doing this the control panel can be armed disarm...

Страница 9: ...l will start in the alarm condition when the power is switch on again If there is any reason to switch the power completely off for example when you want to extend the system with an optional device we recommend to enter the installer programming level at first FACTORY DEFAULT SETTING Master Code 1234 Installer Code 1010 No other access codes programmed Zone definition 1 delay 2 next delay interio...

Страница 10: ...F 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON For Panic alarm y can only be 0 or 2 Panic alarm always activates Panic o Fire alarm aiways activates Fire out ES Ext Siren IS Int Siren 3 xy Alarm outputs definition x alarm default otputs programmed enter y 0 technic Relay 3 0 _ 1 fire ES IS Relay Fire 3 1 _ 2 intruder ES IS Relay 3 2 _ 3 panic Panic 3 3 _ 4 xy System option functions...

Страница 11: ...USER S OPERATION GUIDE OF H 915 Zone location No protected area zone type 1 2 3 4 5 6 Tamper Fire Exit Entry Alarm if troubles call your installer phone H 915 installation manual 11 11 TBT502 01 ...

Страница 12: ...H 915 installation manual 11 12 TBT502 01 ...

Отзывы: