jablotron HESTIA H-915C Скачать руководство пользователя страница 4

 

+BS

 - this terminal is for connection with an outdoor back up siren.  There is a positive potential supplied by this terminal 

when the alarm output relay is not switched on. 

 

C, NC and NO

 terminals are over switching dry contacts for alarm output relay. The maximum load is 1A/60V. The 

function of this relay is programmable for different alarm types (using the [

] [6] installer programming mode). 

 
  

Power: 
+12V, GND

 - back up voltage output for optional devices (motion detectors, telephone dialers etc.). There are two pairs 

of these terminals on the board, both of them are connected together.

 

Maximum current consumption can be 500mA all 

together. The +12V output is protected by a FU2 (1.6A) fuse. 

 

15VAC

 - these terminals are for A.C. power supply connection. Use a transformer with 15VAC output (min. 20VA), or you 

can use the Jablotron PSU-10 adapter. This input is protected by a FU1 (1.6A) fuse. Do not switch the power on before 
the installation is finished!  

 

ACCU.

 - these terminals (+/-) are ready to connect to a back-up battery 12V. Size from 1.2Ah to 40Ah can be used. In 

normal operating mode the control panel charges the battery. Battery input is protected by a FU3 (3.15A) fuse. Do not 
connect the battery before the installation is finished! 

  

Keypad: 

There are three EXT.KEYBOARD terminals to connect to external keypads model H-915K (or other optional 

H-915 device with serial communication). Use three wires to connect the 

A,B and C

 control panel terminals with 

corresponding A,B and C terminals in the keypad. The maximum length of keypad cable should not exceed  50 meters. If 
you use multiple  keypads (a maximum of 5 can be used) connect all of them in parallel. Check carefully that you have 
connected corresponding wires before you turn on the power to the control panel. (The built-in keypad on the H-915C 
model is connected via INT.KEY connector.)  

 

Control panel TAMPER: 

There is a tamper switch  to protect the housing of the control panel. If you have  only the 

H-915B (main board) don't forget to install the attached tamper switch in the housing. 
 

Procedure for Turning on the Power: 

Make a short connection of the RESET link on the board with a jumper.  Connect the back up battery and A.C. power 
supply. Wait 2 seconds and remove the reset jumper. Close the housing of the control panel (connect front panel - only 
model H-915C). 
The control panel will reset to the factory default settings automatically and then will perform a self test. When finished, it 
will be in the installer programming mode. (Press [#] to enter standby). 
 
 

Operation 

There are three levels of operation in the H-915: STANDBY, USER PROGRAMMING and INSTALLER 
PROGRAMMING.   
The

 STANDBY mode

 is the basic working mode of the control panel. It is ready for arming control. The system can be 

directed to perform other functions such as zone bypassing, displaying alarm memory and entering programming level by 
using one of the various [

] commands described below. In STANDBY mode, the zone lights  indicate the triggering of 

zones, or alarm memory with a slow blinking.. 
 

MASTER CODE 

A default master code 1234 is programmed into the H-915 at the factory. The master code is used for arming control as 
other access codes, but only the master code can be used for entering the user programming level ([

] [5] command) and 

for bypassing zones ([

] [8] command). 

 The master code can be reprogrammed by the user, but it can not be removed. 

H-915  installation manual   

11/4 

TBT502 01 

Содержание HESTIA H-915C

Страница 1: ...Security Alarm Control Panel HESTIA 915 installation manual ...

Страница 2: ...uired 12V from 1 2Ah to 40Ah stand by consumption 25mA back up power output 12V max 500mA inputs eight loops FIRE TAMPER and 6 fully programmable loops type of loops balanced with End Of Line resistor 10k remote control inputs digital bus for external keypads programmable optional pulse input outputs overswitching relay contact 1A at 60 V external siren output 0 5A at 12 V backup siren output BS f...

Страница 3: ...nput is also triggered if normally closed contacts wired in series with EOL resistor are opened see the wiring diagram The Fire alarm is activated if a detector connected to a FIRE input is triggered The Tamper alarm can be triggered either by the built in tamper switch control panel keypads or by the tamper switches connected to the TAMP input The definition of zone 1 to 6 delay instant 24hr fire...

Страница 4: ... 5 can be used connect all of them in parallel Check carefully that you have connected corresponding wires before you turn on the power to the control panel The built in keypad on the H 915C model is connected via INT KEY connector Control panel TAMPER There is a tamper switch to protect the housing of the control panel If you have only the H 915B main board don t forget to install the attached ta...

Страница 5: ...on was enabled in the installer programming level If quick arming is enabled the H 915 can be AT HOME armed by entering only the 9 command DISARMING Enter a valid access code to disarm If the chime jumper in the H 915K keypad is connected and you triggered a sensor in a delay zone the keypad buzzer will be beeping In such a case you have only a limited amount of time entrance delay to enter a vali...

Страница 6: ...atically in the moment when used once for arming NOTE If you press 9 in user programming level the H 915 control panel will send information about events history to the special serial interface printer which can be connected to the keypad terminals as an option Only code number 0 master code is programmed from factory the other access codes are blank 6 INSTALLER CODE Entering of INSTALLER PROGRAMM...

Страница 7: ...If the premises is entered without coming through a delay entrance and a next delay loop is triggered an immediate intruder alarm will be generated 05 24Hr silent loop operates as the type 01 but it triggers the PANIC alarm 06 Instant silent loop operates as the type 02 but it triggers the PANIC alarm 07 Delay silent loop operates as the type 03 but it triggers the PANIC alarm 08 Interior instant ...

Страница 8: ...rmed by both sirens The y can only be from 0 to 3 4 1y External arming control with loop 6 input If y 0 zone input 6 will work as programmed in section 1 If y 1 than zone input works as input for external arming and disarming If you close this input with E O L resistor for a moment it will have the same function as entering of a valid access code By doing this the control panel can be armed disarm...

Страница 9: ...l will start in the alarm condition when the power is switch on again If there is any reason to switch the power completely off for example when you want to extend the system with an optional device we recommend to enter the installer programming level at first FACTORY DEFAULT SETTING Master Code 1234 Installer Code 1010 No other access codes programmed Zone definition 1 delay 2 next delay interio...

Страница 10: ...F 3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON For Panic alarm y can only be 0 or 2 Panic alarm always activates Panic o Fire alarm aiways activates Fire out ES Ext Siren IS Int Siren 3 xy Alarm outputs definition x alarm default otputs programmed enter y 0 technic Relay 3 0 _ 1 fire ES IS Relay Fire 3 1 _ 2 intruder ES IS Relay 3 2 _ 3 panic Panic 3 3 _ 4 xy System option functions...

Страница 11: ...USER S OPERATION GUIDE OF H 915 Zone location No protected area zone type 1 2 3 4 5 6 Tamper Fire Exit Entry Alarm if troubles call your installer phone H 915 installation manual 11 11 TBT502 01 ...

Страница 12: ...H 915 installation manual 11 12 TBT502 01 ...

Отзывы: