-8-
7.
ASCII Commands
The JTECH-18EX50 also supports ASCII command control. Connect the
SERVICE port of the product to a PC with a USB cable. Then, open a Serial
Command tool on PC to send ASCII commands to control the product.
The ASCII command list about the product is shown as below.
ASCII Commands
Serial Port Protocol - Baud Rate: 115200 | Data Bits: 8-bit | Stop Bits:1 | Check Bit: 0
x - Parameter 1
y - Parameter 2
! - Delimiter
Command Code
Function Description
Example
Feedback
Default Setting
Power
s power z!
Power on/off the device
z=0~1 (z=0 power off, z=1
power on)
s power 1!
Power on
System Initializing...
Initialization Finished!
FW version x.xx.xx
power on
r power!
Get current power state
r power!
power on/power off
s reboot!
Reboot the device
s reboot!
reboot
System Setup
help!
List all commands
help!
r type!
Get device model
r type!
HDC-SPB18D60
r status!
Get device current status
r status!
Obtain power status,
in/out connection &
EDID mode
information
r fw version!
Get firmware version
r fw version!
MCU BOOT: Vx.xx.xx
MCU APP: Vx.xx.xx
r link in!
Get the connection status of
the input port
r link in!
HDMI IN: connect
r link out y!
Get the connection status of
the y output port
y=0~8(0=all, 1~8=CAT 1~8)
r link out 1!
CAT OUT1: connect
r link loop out y!
Get the connection status of
the y loop output port
|
y=1
r link loop out 1!
HDMI LOOP OUT:
connect
s reset!
Reset to factory defaults
s reset!
Reset to factory
defaults
System Initializing...
Initialization Finished!
FW version x.xx.xx