J Plus, Inc
J Plus Proprietary and Confidential
46/88
7.2.3.3
S1AP
From the tree menu, select S1AP to move onto the S1AP setup page. Insert the number of MME and MME IP
address and click the Save button.
Figure 34: MME Setup
7.2.3.4
MR
From the tree menu, you can select MR to move on to the measurement report setup page. Choose one of trigger
quantities (RSRP, RSRQ, RSCP, Ec/No) from the list. Insert threshold value and click the Save button. Please
refer to Table 12for the detailed input parameter information
.
*
All units are defined reported value from TS36133 (RSRP: 9.1.4, RSRQ: 9.1.7), TS25133 (RSCP: 9.1.1.3, Ec/No: 9.1.2.3).
Menu
Description
Intra-frequency
EUTRAN HO
Select the Event A3 or A4. If you select event A3, then A3 is supported. (Event A4
is the same as A3.)
Inter-frequency
EUTRAN HO
Select the Event A3 or A5. If you select event A3, then A3 is supported. (Event A5
is the same as A3.)
Inter-RAT
HO/Redirect/SRVCC
Select the Event B1 or B2. If you select event B1 then B1 is supported. (Event B2
is the same as B1.)
A1, A3, A4
Select the type of trigger quantities for each event.
A2
Select the type of trigger quantities for each event.
There are 4 options in A2 Event. Inter-freq Ho, Inter-RAT HO/REDIR, SRVCC,
Blind Redirection. If you don't want to use event, then insert 0 in threshold value.
RSRP, range: [0, 97]
Insert RSRP threshold for each event.
RSRQ, range: [0, 34]
Insert RSRQ threshold for each event.
Intra-Freq HO/ANR
range: [-30, 30]
Insert Intra-Freq HO/ANR offset value.