background image

J Plus, Inc

JLT733A User Manual

Version  1.0  Rev.  8

Feb  25,  2020

Copyright©2019 

J Plus, Inc

The information contained herein is the property of 

J  Plus

 and is provided without liability of errors, omissions,

and mistakes. No part maybe reproduced or copied without written permission or contract.

Содержание JLT733A

Страница 1: ...Rev 8 Feb 25 2020 Copyright 2019 J Plus Inc The information contained herein is the property of J Plus and is provided without liability of errors omissions and mistakes No part maybe reproduced or co...

Страница 2: ...J Plus Inc Revision History www juniglobal com J Plus Proprietary and Confidential 2 98...

Страница 3: ...y 20 2 9 3 Management 20 3 Interface and LED Description 21 3 1 Interface and Connector 21 3 2 LED 22 4 Initial Connection 23 4 1 Cable Connection 23 4 2 Connection Test 24 5 Connection via Web GUI 24...

Страница 4: ...2 4 4 Debug Mask Setting 84 6 2 4 5 Analysis Log Report Password Change 85 6 2 4 6 Remote Authentication 86 6 2 4 7 Reboot 87 6 3 Information Menu 88 6 3 1 Update Period 88 6 3 2 Device Info 89 6 3 3...

Страница 5: ...8 Figure 27 eNodeB Private Key and Certificate 41 Figure 28 Trusted CA Certificates 42 Figure 29 CMPv2 43 Figure 30 eNodeB Basic Configuration MENU CA Disable 44 Figure 31 eNodeB Basic Configuration M...

Страница 6: ...n 75 Figure 70 CSG Setup 75 Figure 71 REM SON Setup 76 Figure 72 ESON Setup 77 Figure 73 Save Settings 78 Figure 74 Save Confirmation Window 78 Figure 75 Export Configuration File 79 Figure 76 Import...

Страница 7: ...eb GUI Menu for CA Disabled 28 Table 11 Description of Small Cell Web GUI Menu for CA Enable 30 Table 12 Basic Configuration Parameter Information 47 Table 13 Description of MR parameter 50 Table 14 D...

Страница 8: ...d operating within the commercial LTE network Generally small cell can easily be installed like WiFi AP while Picocell is recommended to be installed after cell planning by wireless operators Figure 1...

Страница 9: ...etwork access including Internet service JLT733A supports IPSec with Security GW when it is deployed in public network It carries out either USIM based or Certificate based authentication procedure fo...

Страница 10: ...HeNB to HeNB Management System HeMS Telecommunication management Home enhanced Node B HeNB Operations 32 593 Administration Maintenance and Provisioning OAM P Procedure flows for Type 1 interface HeN...

Страница 11: ...lved Universal Terrestrial Radio Access Network E UTRAN S1 signaling transport Evolved Universal Terrestrial Radio Access Network E UTRAN S1 Application Protocol 36 413 S1AP 36 414 Evolved Universal T...

Страница 12: ...tions Attach Detach Initial Access Tracking Area Update E RAB Setup E RAB E RAB Release E RAB Modify S1AP Reset S1AP Setup S1AP S1AP MME Configuration Update S1AP eNB Configuration Update www juniglob...

Страница 13: ...lind redirection Manual Neighbor Management ANR Automatic Neighbor Relation function based on UE s measurement Neighbor Management report ANR function based on built in REM function under development...

Страница 14: ...ling Table 4 System Specifications 2 5Environmental Specifications Item Remarks Operating Temp 22 131 Operating Humidity Storage Temp 40 158 Storage Humidity Table 5 Environmental Specifications www j...

Страница 15: ...64QAM RS Power ACLR Spurious Emission Table 6 RF Specifications for DL Transmissions 2 6 2 Uplink Reception for 20MHz BW Item Remarks Frequency Range 10 20MHz BW Sensitivity Others Table 7 RF Specifi...

Страница 16: ...r enters Power AMP module through BALUN and a Filter In Power AMP module the signal is generated as the maximum level and this signal is transmitted via ANT after passing Filter out of band s noise re...

Страница 17: ...erformance Digital Signal Processing DSP array supporting a simplified programming model The device offers hardware acceleration for application specific tasks and a rich set of interfaces and feature...

Страница 18: ...chip T3300 is controlled by RF SPI and I Q data is controlled by LVDS interface E Power The voltage range of power supplied by external source is 9V It goes into power IC DC DC step down converter an...

Страница 19: ...l between HeNBs to handle UE mobility defined in TS 36 423 GTP GPRS Tunneling Protocol Tunneling protocol for user plane defined in TS 29 281 SCTP Stream Control Transmission Protocol Transport protoc...

Страница 20: ...ing X 509 certificates through a PKI Public Key Infrastructure 2 9 3 Management Management Layer provides management capabilities for HeNB and interfaces with upper layer managing entities TR 069 HTTP...

Страница 21: ...lobal com J Plus Proprietary and Confidential 21 98 Interface Type Default value Description WAN RJ 45 10 1 35 210 WAN connection MGMT RJ 45 10 0 0 1 Direct connection for management CMOS UART Debuggi...

Страница 22: ...tion www juniglobal com J Plus Proprietary and Confidential 22 98 LED Intermittent Blink Green Blink Green Solid Green Solid Red Off LTE On Carrying Traffic On Booting Rebooting LTE On LTE Off ALM Ala...

Страница 23: ...router you can configure network as described in Figure 9 and connect the UTP cable from WAN port to the router You can have access to Small Cell through router from Control PC as well using the WAN I...

Страница 24: ...Test from Control PC to Small Cell via local MGMT Port 5 Connection via Web GUI If the Ping test to the management IP address 10 0 0 1 is successful open a Web browser and type http 10 0 0 1 8088 or h...

Страница 25: ...ee menu on the left side has sub menus where the user can configure the settings and check information of the device If you click the sub menus more information related to the categories will be displ...

Страница 26: ...rmation Statistics Report Configure the server information to which statistics data is uploaded Optional Setting Configure the Host name and IP address of the LAN port Static Routing Configure static...

Страница 27: ...lect a new firmware to be upgraded and apply it Log Setting Configure log levels and export volatile non volatile log files Debug mask Setting Configure debug masks used only for engineering purpose P...

Страница 28: ...mation Also Sys time settings Downlink Time Offset is configurable WAN port Configure Ethernet port information Statistics Report Configure the server information to which statistics data is uploaded...

Страница 29: ...Manage system parameters for Small Cell by saving the amended system setting Also a new Configuration File can be imported for updating system setting or the current Settings Configuration File can b...

Страница 30: ...ing status GPS Info Display GPS locking status and information Resolved MME IP Display current MME information RIP Info Display current RIP information SAS Info Display current SAS Information LTE Sta...

Страница 31: ...rface the user can configure Vlan ID Vlan Priority and size of MTU The device supports IPv4 IPv6 A registered Network Interface can be modified and deleted in Registered Network Interfaces Modified Ne...

Страница 32: ...ned to Small Cell On the other hand if Static IP is selected the user can configure the static IP address Subnet Mask Default GW manually IP address configuration can be applied to the system after cl...

Страница 33: ...rmation click Add button Registered Network Interface s information was applied as shown in the Figure 17 and Figure 18 Figure 17 Vlan Configuration Figure 18 Registered Vlan Info Also other VLAN can...

Страница 34: ...dded in Network Interface Menu into each Interface in Network Function Setting page Click Save button and OK button to apply your change Figure 19 Network Function 6 2 1 3 Security Gateway When Small...

Страница 35: ...the new configuration must be saved Figure 24 DHCP Server setup 6 2 1 5 CWMP From the tree menu select CWMP to move onto the CWMP Setup page for configuring enable disable of CWMP and HeMS server IP a...

Страница 36: ...uring Disable Enable IEEE1588 Holdover Time and the number of Master IP Air Sync configuring Disable Enable Also Downlink Time Offset can be configured After changing Clock sync and Sys time settings...

Страница 37: ...6 2 1 8 Statistics Report Statistic Report should be configured to transfer the statistic of Small Cell to statistic management server e g HeMS server From the tree menu select Statistics Report to mo...

Страница 38: ...ick Apply the new configuration must be saved Figure 25 Optional Setting 6 2 1 10 Static Routing From the tree menu the user can add delete the Static Routing menu To configure the static route inform...

Страница 39: ...SAS setup and click Apply the new configuration must be saved 6 2 2 PKI Menu PKI Public Key Infrastructure section controls eNodeB private key and certificate CA certificate and CMP request messages T...

Страница 40: ...mport an eNodeB certificate which must be paired with the private key imported above The box displays the information of current eNodeB certificate stored in the eNodeB If any exists current certifica...

Страница 41: ...J Plus Inc Figure 27 eNodeB Private Key and Certificate www juniglobal com J Plus Proprietary and Confidential 41 98...

Страница 42: ...send Key Update Request KUR to CMP server depending on KUR days In the second table named CMPv2 Request all the CMP actions can be handled manually There are three request options can be chosen one at...

Страница 43: ...certificate renewal sends Key Update Request message for prompt Key Update In the Result of CMPv2 Request page it shows the information and or logs of actions done by the three options above Figure 29...

Страница 44: ...cell configuration is shown as shown in Figure 30 below When CA is enabled two cell CELL1 CELL2 configurations are displayed as shown in Figure 31 below Figure 30 eNodeB Basic Configuration MENU CA Di...

Страница 45: ...J Plus Inc CA Enable Cell 1 CA Enable Cell 2 Figure 31 eNodeB Basic Configuration MENU CA Enable www juniglobal com J Plus Proprietary and Confidential 45 98...

Страница 46: ...nc CA enable disable can be set in the CA menu as shown Figure 32 below CA Enable to Disable CA Disable to Enable Figure 32 CA Enable Disable MENU www juniglobal com J Plus Proprietary and Confidentia...

Страница 47: ...MNC Subframe Assignment Defines the DL UL subframe configuration for TD LTE Special Subframe Patterns Defines the configuration of the special subframe for TD LTE E UTRA frequency DL UL EARFCN DL UL...

Страница 48: ...ed ON only if the Small Cell has the S1 connection with MME The red BLOCK status as shown in Figure 34 indicates the RF is turned off but can be switched on by clicking UN BLOCK button RF can be switc...

Страница 49: ...S1AP From the tree menu select S1AP to move onto the S1AP setup page Insert the number of MME and MME IP address and click the Save button Figure 35 MME Setup www juniglobal com J Plus Proprietary and...

Отзывы: