For Your Safe Flight
Page | 42
HP Constants
Hold
NEXT
and button 2 for 5
seconds until you see
ADJUST
rich of peak or lean of peak
constants. Tap
ROP
to proceed to
Rich of Peak ‘HP Constant’ setting.
Tap
LOP
to proceed to Lean of
Peak ‘Engine Constant’ setting.
HP Constant= 125
10
999
Hold
NEXT
and button 2 until you
see
ADJUST
. Tap
PLUS
or
MINUS
to adjust (%HP display will
reflect changes). Hold
NEXT
and
button 2 to save changes.
Engine Constant =
14.9
1
99.9
Hold
NEXT
and button until you
see
ADJUST
. Tap
PLUS
or
MINUS
to adjust. Hold
NEXT
and
button 2 to save changes.
Engine HP = 225
10
999
Set the nominal horsepower of
your engine. This value will be
multiplied by the %HP to display
HP. Hold
NEXT
and button 2 for 5
seconds until you see
ADJUST
.
Use
PLUS
or
MINUS
to adjust.
Tap
SAVE
to save changes. Tap
NEXT
to skip to next item.
Lft MAP
Rht MAP
-3.0
+3.0
Correct the MAP to the altimeter
setting at a sea level airport ±3.0
inHg. Hold
NEXT
and button 2 for
5 seconds until you see
ADJUST
.
Use
PLUS
or
MINUS
to adjust.
Tap
SAVE
to save changes. Tap
NEXT
to skip to next item.
Lft K-Factor 1= 29.90
Rht K-Factor 1= 29.90
00.10
99.99
Set
the instrument’s K-factor to
match the fuel flow transducer K-
factor and performance. Hold
NEXT
and button 2 for 5 seconds
until you see
ADJUST
. Use
DIGIT
,
PLUS
or
MINUS
to adjust. Hold
NEXT
and button 2 to save
changes.