Troubleshooting:
Problem Possible
cause
Solution
Breaker inside fuse panel is not in the on position.
Turn breaker on.
No power to machine.
Check incoming power line voltage.
Machine power switch is not on.
Remove dome and flip switch.
Loose connection.
Check incoming power connection.
Air is leaking from unit somewhere.
Turn power off to unit, apply chuck to air
source with at least 30lbs of pressure and
listen carefully for leaks inside cabinet or air
hose.
Chuck washer is worn out?
Replace rubber washer inside chuck with JE
Adams PN 8533-3CW.
Wrong size breaker or other components running on
same circuit.
Install correct breaker for compressor and
make sure line is a dedicated power source.
Compressor or timer might be shorted out?
Isolate problem component and replace if
necessary.
Check key components to isolate failure:
Timer:
Verify proper input voltage. Activate
timer. If no output voltage is present when
timer should be active, replace timer.
Coin mech:
If using a mechanical coin mech,
remove the wires leading to the timer from the
coin mech and tap the together one time for
each coin necessary to start the timer. If
machine starts, replace the coin mech.
Unit is not powered.
Unit keeps tripping
breaker from
incoming power
source
Unit runs but will not
inflate tire.
Unit will not start
Possible component failure
ALWAYS DISCONNECT POWER BEFORE TROUBLESHOOTING!!