Troubleshooting:

Problem Possible 

cause

Solution

Breaker inside fuse panel is not in the on position.

Turn breaker on.

No power to machine.

Check incoming power line voltage.

Machine power switch is not on.

Remove dome and flip switch.

Loose connection.

Check incoming power connection.

Air is leaking from unit somewhere.

Turn power off to unit, apply chuck to air 
source with at least 30lbs of pressure and 
listen carefully for leaks inside cabinet or air 
hose.

Chuck washer is worn out?

Replace rubber washer inside chuck with JE 
Adams PN 8533-3CW.

Wrong size breaker or other components running on 
same circuit.

Install correct breaker for compressor and 
make sure line is a dedicated power source.

Compressor or timer might be shorted out?

Isolate problem component and replace if 
necessary.

Check key components to isolate failure:

Timer: 

 Verify proper input voltage.  Activate 

timer.  If no output voltage is present when 
timer should be active, replace timer.

Coin mech:

 If using a mechanical coin mech, 

remove the wires leading to the timer from the 
coin mech and tap the together one time for 
each coin necessary to start the timer.  If 
machine starts, replace the coin mech.

Unit is not powered.

Unit keeps tripping 

breaker from 

incoming power 

source

Unit runs but will not 

inflate tire.

Unit will not start

Possible component failure

ALWAYS DISCONNECT POWER BEFORE TROUBLESHOOTING!!

Содержание 9670

Страница 1: ...duct Information Page 3 Specifications Page 4 Important Safety Instructions Page 5 Product Dimensions Page 6 8 Installation Page 9 Timer Set Up Page 10 Operating Instructions Maintenance Page 11 Troubleshooting Page 12 13 Parts List Wiring Diagrams ...

Страница 2: ...n the lower exterior of the can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records MODEL ____________________________ SERIAL ____________________________ KEY NUMBER S _____________________ DATE PURCHASED ___________________ DISTRIBUTOR _______________________ J E Adams Industries ...

Страница 3: ...ice is required for this unit Compressor hp twin cylinder Timer SSAC Weight 68lbs with dome Locks 2 High Security Medeco cam lock DUTY CYCLE 4 minutes on 4 minutes off Optional accessories NOTE UNIT INTENDED FOR COMMECIAL USE ONLY Wall mount pedestal 8819 60 Lock bar kit 9670 24A Floor mount pedestal 8819 50 ...

Страница 4: ...r smoking such as cigarettes matches or hot ashes SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS SUCH AS SWITCHES MOTORS OR THE LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN CAUSE AN EXPLOSION WHEN LOCATED IN GASOLINE DISPENSING AND SERVICE STATIONS INSTALL AND USE AT LEAST 20 FEET 6 M HORIZONTALLY FROM THE EXTERIOR E...

Страница 5: ...REV A 8 26 2011 5 PRODUCT DIMENSIONS Wall mount pedestal option Floor mount pedestal option ...

Страница 6: ...nformation Installation bolt pattern If mounting to hollow concrete block proper hardware must be used 5 16 Ex split sleeve wall anchor toggle bolts etc Solid concrete can use red head type anchors Floor mount pedestal Wall mount pedestal ...

Страница 7: ... of machine Allow enough extra wire on top to tie into the factory wiring pictured on next page Once pedestal is mounted set air machine onto pedestal and open door to access inside of machine Bolts will line up through bottom of cabinet Attach with supplied hardware 4 nuts ...

Страница 8: ...REV A 8 26 2011 8 NOTE AIR MACHINE SHOULD BE INSTALLED PER LOCAL ELECTRICAL CODES BY QUALIFIED ELECTRICIAN Wire nut 120VAC black to black white to white Add green ground wire to stud provided ...

Страница 9: ...ich requires dip switches 3 2 and 8 to be set to on This scenario means 1 quarter will provide 4 minutes of vacuum time The time per coin setting can be modified as desired by simply adding or subtracting time If the operator would later decide to increase the cost of the unit to 2 quarters the 2 dip switch would need to be in the on position all other off and the time dip switches would need to h...

Страница 10: ...ducted by an authorized service representative Periodically inspect hose chuck and chuck washer for wear or fatigue Every month remove filter from compressor and clean Periodically inspect electrical wires and connections for wear or fatigue Clean canister with a stainless steel cleaner as needed Decals can be cleaned with mild soap and water Replacement parts can be ordered through JE Adams or yo...

Страница 11: ...ponents running on same circuit Install correct breaker for compressor and make sure line is a dedicated power source Compressor or timer might be shorted out Isolate problem component and replace if necessary Check key components to isolate failure Timer Verify proper input voltage Activate timer If no output voltage is present when timer should be active replace timer Coin mech If using a mechan...

Страница 12: ...REV A 8 26 2011 12 ...

Страница 13: ...REV A 8 26 2011 13 ...

Отзывы: