background image

REV 8-22-19 

11 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inadequate wire size ran to machine.

Call electrician and install proper wire size for 
electrical service versus length or run.

Wrong size breaker.

Install correct breaker (only if wire size is 
adequate to handle breaker).

Inadequate wire size ran to machine.

Call electrician and install proper wire size for 
electrical service versus length or run.

Motor brushes may be bad or too short.

Replace motor brushes.

Vac hose clogged?

Clean debris from vac hose.

Filter bags need cleaned or dirt chamber needs emptied?

Shake or clean filter bags or replace and empty 
lower dirt chamber.

Vac hose is split?

Replace/repair vac hose.

Cleanout door gaskets torn or worn?

Replace gaskets.

Vac motor gaskets are worn or motor is not tight against.

Inspect/replace gaskets and assure motor is 
tight against them.

Lower chamber cap plugs/mounting hole covers have 
popped out?

Open lower chamber and inspect plugs, order 
new if needed.

Cleanout door gaskets torn or worn?

Replace gaskets.

One of the vac motors is not working?

Check line motor fuse and replace.  Replace 
motor if necessary.

Lack of vacuum suction.

Unit keeps tripping 
breaker.

Fuses for vac motors keep 
blowing.

Содержание 8200

Страница 1: ...Product Information Page 3 Specifications Page 4 Important Safety Instructions Page 5 Product Dimensions Page 6 8 Installation Page 8 9 Programming Page 10 Operating Instructions Page 10 11 Maintenanc...

Страница 2: ...he lower exterior of the can Key number can be found on the tag that comes attached to the keys There may be more than one key number depending on unit Please keep this information with your records M...

Страница 3: ...10 amp inline fuses __________________________________________________________________________________________ 220VAC units Unit specifications All 2 vacuum motor units Voltage 220VAC 50Hz Amperage 1...

Страница 4: ...tes matches or hot ashes Do not use without dust bag and or filters in place SAVE THESE INSTRUCTIONS Installation Instructions Determine location to mount unit DANGER THIS EQUIPMENT INCORPORATES PARTS...

Страница 5: ...REV 8 22 19 5 Product Dimensions 8600LD...

Страница 6: ...Installation Drill holes into concrete surface and install 3 8 studs 4 NOTE when mounting provide clearance so cleanout door can open Bring electrical in underneath can and route up front channel to t...

Страница 7: ...erneath can and route up front channel to terminal strip With timer plate flipped down as shown add incoming power line and neutral to terminal strip 120V Remove screw from uppermost point of timer pl...

Страница 8: ...it has been installed use 5871B8 cap plugs supplied with unit to seal holes in canister bottom located in lower cleanout door Extra cap plugs are included with the unit in case plug becomes damaged du...

Страница 9: ...s which requires dip switches 3 2 and 8 to be set to on This scenario means 1 quarter will provide 4 minutes of vacuum time The time per coin setting can be modified as desired by simply adding or sub...

Страница 10: ...ks on a weekly basis Clean canister with a stainless steel cleaner as needed Decals can be cleaned with mild soap and water Check motor brushes every month for excessive wear Motor brushes should be c...

Страница 11: ...need cleaned or dirt chamber needs emptied Shake or clean filter bags or replace and empty lower dirt chamber Vac hose is split Replace repair vac hose Cleanout door gaskets torn or worn Replace gaske...

Страница 12: ...REV 8 22 19 12...

Страница 13: ...REV 8 22 19 13...

Страница 14: ...REV 8 22 19 14...

Страница 15: ...REV 8 22 19 15...

Страница 16: ...REV 8 22 19 16...

Страница 17: ...REV 8 22 19 17...

Страница 18: ...REV 8 22 19 18...

Страница 19: ...REV 8 22 19 19...

Страница 20: ...REV 8 22 19 20 Model 8105 Toggle Switch option...

Отзывы: