Storage Procedure:
1) Disconnect the water hose from the unit inlet fitting.
2) Install the winterization adapter, J.E. Adams Pn 6687T001, on the water hose inlet
fitting.
3) Connect a compressed air source to the winterization adapter. Do not use
compressed air at more than 100 Psig.
4)
DO NOT LEAVE THE UNIT UNATTENDED DURING THE FOLLOWING STEPS:
a) Switch the Pump “ON” briefly to clear the system of water. The system will be
clear when the column connector discharges air only from the unit.
b) Stop the pump immediately when the water has been eliminated.
DO NOT RUN
THE UNIT WITHOUT WATER.
c) Plug all water fitting openings and protect the nozzle fittings from damage.
d) Wipe down the entire unit to remove excess water droplets.
5) Disconnect the electrical power cord and store on the power cord take-up located on
the rear of the column.
6) Store the unit in a clean, secure location.