8) Connect the power cord to 120V electrical power.
9) It is highly recommended that the power source be protected by a Ground Fault
Circuit Interrupter type circuit breaker.
10) When allowed by local authorities, you may extend your fan location, up to 100 feet,
using an appropriate g
auged electrical cord.
11) Turn the fan “on.”
12) Turn the misting pump “on” to produce the “flash-cooling” effect.
Maintenance:
D
ISCONNECT ALL ELECTRICAL POWER AND THE SOURCE WATER HOSE PRIOR TO PERFORMING
ANY MAINTENANCE
.
1) F
AN
U
NIT MAINTENANCE
:
a) Periodically, the fan unit shroud and guards should be cleaned with a mild
detergent and wiped completely dry.
i) Periodically, check the misting nozzles performance.
ii) If the misting cone is deformed or absent, clean the nozzles, using 1 cup of
"hot" water, 1 cup of 5% vinegar.
iii) Soak nozzles for 10 minutes.
iv) Install on unit and run pump immediately to flush out.
v) Compressed air may also work as an alternative.
vi) Replace the nozzles if necessary.
b) Periodically, check the electrical power cord for abrasions, cracking or other wear.
Replace as necessary.
c) Periodically, check the high pressure water line for leaks, or other signs of wear.
Replace as necessary.
d) When the pump runs intermittently, the particulate filter element needs to be
replaced. In any event, replace the particulate filter element seasonally.
e) The external Water Conditioner cartridge should be replaced whenever the
misting nozzles show signs of “liming up,” or seasonally, whichever comes first.
2) P
UMP
U
NIT MAINTENANCE
:
a) The internal Sediment filter cartridge should be replaced if the misting pump runs
intermittently, or seasonally, whichever comes first.
b) The water pump oil should be replaced after the first 50 hours of operational time.
c) Subsequent oil changes should occur after every 500 hours of operational time or
seasonally, whichever comes first.
d) Use 10 oz. CAT pump oil per change. J.E. ADAMS Industries, Ltd. Pn 6611B013.
Do not fill above the center of the oil viewing glass.
e) Install the base cover prior to using the unit.
R
ECONNECT THE WATER HOSE AND THE ELECTRICAL POWER CORD WHEN DESIRED
.