background image

8)  Connect the power cord to 120V electrical power. 

9)  It is highly recommended that the power source be protected by a Ground Fault 

Circuit Interrupter type circuit breaker.  

10)  When allowed by local authorities, you may extend your fan location, up to 100 feet, 

using an appropriate g

auged electrical cord.  

  

11) Turn the fan “on. 

12) Turn the misting pump “on” to produce the “flash-cooling” effect. 

 
 Maintenance: 

 

D

ISCONNECT ALL ELECTRICAL POWER AND THE SOURCE WATER HOSE PRIOR TO PERFORMING 

ANY MAINTENANCE

.  

 

1) F

AN 

U

NIT MAINTENANCE

a) Periodically, the fan unit shroud and guards should be cleaned with a mild 

detergent and wiped completely dry. 

i)  Periodically, check the misting nozzles performance. 

ii)  If the misting cone is deformed or absent, clean the nozzles, using 1 cup of 

"hot" water, 1 cup of 5% vinegar. 

iii)  Soak nozzles for 10 minutes. 

iv)  Install on unit and run pump immediately to flush out.   

v)  Compressed air may also work as an alternative. 

vi)   Replace the nozzles if necessary. 

b)  Periodically, check the electrical power cord for abrasions, cracking or other wear.  

Replace as necessary. 

c)  Periodically, check the high pressure water line for leaks, or other signs of wear.  

Replace as necessary. 

d) When the pump runs intermittently, the particulate filter element needs to be 

replaced.  In any event, replace the particulate filter element seasonally. 

e) The external Water Conditioner cartridge should be replaced whenever the 

misting nozzles show signs of “liming up,” or seasonally, whichever comes first. 

2) P

UMP 

U

NIT MAINTENANCE

a)  The internal Sediment filter cartridge should be replaced if the misting pump runs 

intermittently, or seasonally, whichever comes first. 

b)  The water pump oil should be replaced after the first 50 hours of operational time. 

c)  Subsequent oil changes should occur after every 500 hours of operational time or 

seasonally, whichever comes first. 

d)  Use 10 oz. CAT pump oil per change.  J.E. ADAMS Industries, Ltd. Pn 6611B013.  

Do not fill above the center of the oil viewing glass. 

e)  Install the base cover prior to using the unit. 

R

ECONNECT THE WATER HOSE AND THE ELECTRICAL POWER CORD WHEN DESIRED

                                                                                                  

Содержание 6700A

Страница 1: ...N 5 HP motor 120 Volts 7 4 Amps 60hz 1725rpm PUMP 10 9 Amps total 1 dedicated 15A power supply required 5 gpm pump 1725rpm Motor pump combination supports 18 nozzles Dual filtration 5 10 micron filter housing uses standard garden hose water connection for easy hook up ...

Страница 2: ... an RV water pressure regulator locally to reduce the inlet water pressure to 50 55 Psig if your potable water pressure exceeds 125 Psig and install it at the cooling fan water inlet 5 The aqua breeze cooling fan is now ready for operation Operation of Unit 1 Select an unobstructed location 2 Connect the hose to the closed inlet shut off valve and turn the source water on full open 3 Open the inle...

Страница 3: ... nozzles if necessary b Periodically check the electrical power cord for abrasions cracking or other wear Replace as necessary c Periodically check the high pressure water line for leaks or other signs of wear Replace as necessary d When the pump runs intermittently the particulate filter element needs to be replaced In any event replace the particulate filter element seasonally e The external Wat...

Страница 4: ...EPS a Switch the Pump ON briefly to clear the system of water The system will be clear when the column connector discharges air only from the unit b Stop the pump immediately when the water has been eliminated DO NOT RUN THE UNIT WITHOUT WATER c Plug all water fitting openings and protect the nozzle fittings from damage d Wipe down the entire unit to remove excess water droplets 5 Disconnect the e...

Страница 5: ...valves If any have been closed the pump will stop automatically and the safety pressure switch will be ON It is normal for the pump motor to feel hot If the pump motor is not running verify that the safety pressure switch light is OFF This will be likely to happen to a pump motor if the discharge pressure has been set too high Set the pressure regulator to 700 Psig maximum In any event do not exce...

Отзывы: