Aqua Breeze™ Instructions Mobile II Cooling Fan 

 

Initial Setup of the Unit: 

 

1) After assembly: Remove the fan sub-assembly and hardware from the shipping carton. 

a)  The fan may be tilted to four separate positions by pulling the pin on the side of 

the fan mount, tilting the fan to the required position and inserting the hitch pin.   

b) DO NOT ATTEMPT TO ADJUST FAN TILT WHILE THE FAN IS RUNNING.  

SERIOUS INJURY MAY OCCUR.   

c)  Connect the fan cord, finger tight, to the fan outlet near the top of the column. 

2)  Connect your water inlet hose (Not provided by J.E. ADAMS Industries, Ltd. to a 

potable water source capable of delivering at least 1/2 gallon per minute of water at a 
pressure not less than 20 Psig and not more than 125 Psig.   

3) Important:  The water source must be free of pressure surges caused by other 

equipment.  Pressure surges may cause air to become entrained in the water supply.  
Running the pump under a dry condition will void the warranty on the pump 
assembly. 

4)  Purchase an RV water pressure regulator locally to reduce the inlet water pressure to 

50-55 Psig if your potable water pressure exceeds 125 Psig and install it at the 
cooling fan water inlet.  

5)  The aqua-breeze-cooling fan is now ready for operation. 

 

Operation of Unit: 

1)  Select an unobstructed location.   

2)  Connect the hose to the closed inlet shut-off valve and turn the source water on full 

open. 

3)  Open the inlet shut-off valve slightly and eliminate all air from the hose. Close the 

valve once the air is eliminated. Connect the inlet shut-off valve to the cooling fan 
water inlet and open the valve 

4)  Select fan oscillation: 90

o

, 45

or 0

before operating the unit. 

5)  If the fan should be oscillating and is not oscillating, disconnect the electrical power 

and hand tighten knob on top of the fan motor. Turn clockwise to 100 inch pounds.  If 
the unit still will not oscillate after restarting, the oscillator mechanism may need to be 
replaced. 

6) DO NOT ATTEMPT TO ADJUST FAN TILT WHILE THE FAN IS RUNNING.  

SERIOUS INJURY MAY OCCUR. 

7)  The fan may be tilted in four positions by pulling the pin on the side of the fan mount, 

tilting the fan to the required position and reinserting the pin. 

                                                                                                  

Содержание 6700A

Страница 1: ...N 5 HP motor 120 Volts 7 4 Amps 60hz 1725rpm PUMP 10 9 Amps total 1 dedicated 15A power supply required 5 gpm pump 1725rpm Motor pump combination supports 18 nozzles Dual filtration 5 10 micron filter housing uses standard garden hose water connection for easy hook up ...

Страница 2: ... an RV water pressure regulator locally to reduce the inlet water pressure to 50 55 Psig if your potable water pressure exceeds 125 Psig and install it at the cooling fan water inlet 5 The aqua breeze cooling fan is now ready for operation Operation of Unit 1 Select an unobstructed location 2 Connect the hose to the closed inlet shut off valve and turn the source water on full open 3 Open the inle...

Страница 3: ... nozzles if necessary b Periodically check the electrical power cord for abrasions cracking or other wear Replace as necessary c Periodically check the high pressure water line for leaks or other signs of wear Replace as necessary d When the pump runs intermittently the particulate filter element needs to be replaced In any event replace the particulate filter element seasonally e The external Wat...

Страница 4: ...EPS a Switch the Pump ON briefly to clear the system of water The system will be clear when the column connector discharges air only from the unit b Stop the pump immediately when the water has been eliminated DO NOT RUN THE UNIT WITHOUT WATER c Plug all water fitting openings and protect the nozzle fittings from damage d Wipe down the entire unit to remove excess water droplets 5 Disconnect the e...

Страница 5: ...valves If any have been closed the pump will stop automatically and the safety pressure switch will be ON It is normal for the pump motor to feel hot If the pump motor is not running verify that the safety pressure switch light is OFF This will be likely to happen to a pump motor if the discharge pressure has been set too high Set the pressure regulator to 700 Psig maximum In any event do not exce...

Отзывы: