EN
88
Technical Data
Nominal voltage
220V – 240V DC, 50/60 Hz
Rated power
1400 W
Max. power
1600 W
Max. current of connected tools
10 A
Degree of protection
IP24
Dust category
M
Air flow (at the fan)
75 l/s
Air flow (at the hose)
45 l/s
Negative pressure (at the fan)
280 hPa/MG
Negative pressure (at the hose)
245 hPa/MG
Sound pressure level (L
pA
)
≤ 70 dB(A)
Net weight
12.1 kg
Dimensions (L x W x H)
53 x 40 x 56 cm
Troubleshooting
Problem
Cause
Solution
Reduced suction
filter contaminated
Clean
Filter bag full
Change
Container full
Empty
Nozzle, pipes or hose blocked
Clean
Cleaner doesn’t start
Mains plug not plugged in
Plug in
Mains power missing
Check power supply
Mains cable defective
Replace cable
Cover is not entirely closed
Close cover
Container is full
Switch off, remove water from
container, switch on again
Mode selector in position 0
or in position A or RA without
connected and running tool
Turn selector to I
Cleaner doesn’t start along
with connected tool, although
in A or RA mode
Tool is not connected to outlet
socket of cleaner
Connect tool to outlet socket
of cleaner
Solenoid valve defective
Contact customer service
PE collection bag sucked
against the filter
Rotary slide inside container is
set to CLOSE
Set the rotary slide to OPEN for
PE collection bags.
Dust in container after usage
of fleece filter bag
Rotary slide inside container is
set to OPEN
Set the rotary slide to CLOSE
for fleece filter bags.