8
Minimums clearances to combustible
material
This appliance needs a minimum space because of these
reduced clearances. Whether in the living room or the dining
room, the
stove
will match perfectly by its originality and
heating. It requires a minimum clearance of 10 inches at the
back (
for a smoke simple pipe with a heat shield
) and 20
inches of lateral
MINIMUM
clearance.
In case of a single pipe without heat shield, you must keep
your single smoke pipe 18 inches away from all
combustible material so that the MINIMUM clearance at the
back of the top stove will be 16 inches (40.6cm).
Regarding reducing that dimension, you must
contact your local authority to know how to install
heat shield on a wall. Installation with reduced
clearances must comply with standard CAN/CSA-
B365.