Always use dried wood. Do not burn green or wet wood. Do not use construction debris 
such as pieces of 2x4, plywood... 
 
If  the  appliance  starts  to  blush,  it's  because  it  is  too  charged.  Do  not  add  fuel. 
Immediately close the doors and the wall thermostat so all the air intakes of the appliance 
are closed until everything becomes normal again. 
 
Do not load the appliance beyond the firebricks height.

 

 
Ashes must be evacuated frequently, put in a steel container provided with a tight lid and 
be placed outside at once. You must never place other waste in this container.

 

 
Considering the need of air for the combustion, a window or a door must be half opened 
sometimes (fresh air drainage) to balance the pressure in the house, especially if: 
 

 

A fan already evacuates air towards outside (kitchen, bathroom.) 

 

You  want  to  avoid  a  repression  of  smoke  when  lighting  the  appliance  and  when 

reloading the wood. 
 
It is recommended to have a smoke detector near the appliance. 
 
You should contact your municipal or provincial fire department to have knowledge 
of  the  procedure  to  be  followed  in  case  of  a  chimney  fire.  Think  of  an  emergency 
plan. 
 
In case of a chimney fire: 
 

 

Hermetically close the doors and the air intakes. 

 

Water the combustible material adjacent to the chimney. 

 

Ring the alarm, evacuate the house if necessary and call the firemen. 

 

Never touch the pipes until the fire is not completely extinct. 

 

Do not use the chimney until it has been inspected or repaired. 

 
Keep  all  the  doors  closed  while  the  appliance  is  in  function.  Frequently  verify  the 
ceramics cords; they must always be in good condition. 
 
The  chimney  pipe  should  not  pass  close  to  water,  gas  or  oil  pipes,  not  close  to  electric 
wire or other types of ducts, of combustible materials in the roofs, the attics, the walls or 
the  floors.  If  you  have  to  make  it  pass  through  a  wall  or  a  part  of  combustible 
construction,  do  not  forget  that  the  installation  must  be  in  accordance  with  the 
CAN/CSA-B365. Use at least 12 feet of a 6 inches diameter vertical chimney. 
 
NOTE: 

 

FOLLOW  THESE  INSTRUCTIONS  IN  ORDER  TO  AVOID  FIRE  HAZARDS, 
WOUNDS AND PROPERTY DAMAGES. 

Содержание GRIZZLY

Страница 1: ...ZLY FURNACE October 17 2014 Reviewed WOOD FURNACE 1 490 rue de l Argon Quebec Qc Canada G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com Certified and tested according to CAN CSA B415 1 norm...

Страница 2: ...EDRAL ROOF 10 CROSS STYLE INSTALLATION 10 VERTICAL INSTALLATION 11 CLEARANCES 12 INSTALLATION OF THE FIREBRICKS 13 FANS AND THERMODISC 16 HOW TO PLUG THE THERMOSTAT DIRECTLY INTO THE TERMINAL BOARD 17...

Страница 3: ...IFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID FUEL BURNING A...

Страница 4: ...plenum 52 in 133cm with plenum Exterior width 29 1 8 in 74 cm without electrical box 33 5 8 in 85 7cm with electrical box Exterior depth 39 1 8 in 99 4cm without fan box 48 7 8 in 124 14cm with fan b...

Страница 5: ...room where the appliance must be installed must measure a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior...

Страница 6: ...pliance You should contact your municipal or provincial fire department to have knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire...

Страница 7: ...first hours of utilization It is normal that a light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensur...

Страница 8: ...ight and by reducing the heat loss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the ef...

Страница 9: ...cal laws or the CAN CSA B365 ULC S635 ULC S640 UL 1777 norms Install the chimney following the manufacturer s instructions Exterior vertical installation The GRIZZLY Furnace wood appliance must be ins...

Страница 10: ...applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instructions Cross style installation The GRIZZLY Furnace wood appliance must be installed in accordanc...

Страница 11: ...rtical installation The GRIZZLY Furnace wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instruct...

Страница 12: ...atter where you install it this appliance will perfectly complete your decoration by its originality and its heat This appliance only needs a 1 inch clearance at its back 6 inches from the lateral wal...

Страница 13: ...rew to secure the bricks on the interior wall of the furnace 1 Install the bricks in the bottom of the stove horizontal Bricks A 12x Bricks F 2x Bricks E 1x 2 Install the bricks against both lateral w...

Страница 14: ...the front of the stove See figure 1 above 6 Fix the pipes support in the stove using the hex head screw provided See figure 2 7 Insert the 2 other pipes in the stove passing them trough the hook of t...

Страница 15: ...15 Make sure that the rockwhool is properly installed In the bottom of the furnace and without prejuidice with the deflector FIGURE 3...

Страница 16: ...bution of heat in your home When the appliance is in function and that conduct reaches a temperature of 1600F the FS160 thermodisc will close the air entry without stopping the fan in order to slow do...

Страница 17: ...n box on the side of the furnace Join the black wire of the thermostat with the black wire in the junction box and then protect them with a wire nut Join the white wire of the junction box and the whi...

Страница 18: ...x the front cover in front of the furnace with 4 screws 4 Fix the wire support on the side of the furnace with 2 screws 5 Fan installation Remove the fan box cover 4 screws Remove the steel plate if i...

Страница 19: ...hat no electrical wire can touch to the hot side of the furnace 7 Install the chain linking to the electrical box with the air intake damper Just hook the chain of the damper to the hole of the electr...

Страница 20: ...rews 2 After fix the electrical wire with the nylon bushings Follow the next step 1 Insert the wire in the nylon bushing 2 Close the bushing 3 Insert the bushing in the hole of the protection plate WA...

Страница 21: ...equipped with a direct vent door and give access to the heat exchanger When the door is open the heat goes in the room of the furnace If there is a power outage the furnace gives heating in the room T...

Страница 22: ...as ceramics marble or granite LIGHTING Now that you have completed the installation of the appliance according to the recommendations you are ready for the lighting 1 Place papers and small wood in t...

Страница 23: ...aft control a smoke return a bad combustion and a counter blow even though you have combustion or not Your other appliances such as hearths or other heating appliances release odors heat badly provoke...

Страница 24: ...appliance AIR SUPPLY A new air supply can be done by the following ways Indirect method In the case of an appliance not certified for a direct connection with a source of new air supply the new air i...

Страница 25: ...ot use a paper towel to clean gildings If they are not erased before the first fire fingerprints and other marks could stain these surfaces permanently 7 The Atmosphere is provided with an ashtray und...

Страница 26: ...ICK INTERIOR PIPE GLASS BRICK S SUPPORT DOOR HANDLE APPLIANCE S DOOR FANS SEALANT CORDS FAN CONTROL MODULE DAMPER MOTOR TRANSFORMATOR THERMOSTAT BUTTERFLY VALVE AIR ENTRY STALK TO ORDER PARTS PLEASE C...

Страница 27: ...ted to warranty repair are not covered The manufacturer may at its discretion decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its...

Страница 28: ......

Отзывы: