background image

Application Note: ZMOTION

TM

 Detection Module Evaluation Kit 

 

 
QS007306-0810

 

 

2 of 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1. ZMOTION

TM

 Detection Module Evaluation Kit Components 

Setting up for Initial Operation 

The simplest mode in which to use the module is “Hardware Mode”. In this mode the sensitivity, ambient light 
level and LED ‘On” time are all adjusted using the controls on the Base Board. There are a few simple steps 
needed to start using the kit in Hardware Mode: 

 

Step 1: Unpack the hardware components 

 

Step 2: Insert the ZMOTION Detection Module into the Base Board 

 

Step 3: Install the correct AC adapter into the universal supply 

 

Step 4: Ensure the jumpers, switches and potentiometers on the base board are in the correct positions 

 

Step 5: Apply power 

 

Step 6: Demonstrate - Wait about 30 seconds (possibly less), generate motion in front of the module 

and look for the blue LED to turn on 

Содержание Zilog ZMOTION

Страница 1: ...dware mode For additional information please refer to the ZMOTIONTM Detection Module Evaluation Kit Users Manual UM0223 Kit Contents Hardware The ZMOTIONTM Detection Module Evaluation Kit includes the following hardware ZMOTIONTM Detection Module Base Board ZMOTIONTM Detection Module RS 232 Serial Cable DB9 DB9 5V DC Universal Power Supply Documentation The related technical documentation on CD RO...

Страница 2: ...g the controls on the Base Board There are a few simple steps needed to start using the kit in Hardware Mode Step 1 Unpack the hardware components Step 2 Insert the ZMOTION Detection Module into the Base Board Step 3 Install the correct AC adapter into the universal supply Step 4 Ensure the jumpers switches and potentiometers on the base board are in the correct positions Step 5 Apply power Step 6...

Страница 3: ...stall the AC Plug Adapter The universal power supply kit features four different plug adapters in one box and the power supply by itself in another The power supply ships with a slide out plate that must be removed to insert the location specific plug adapter Follow the steps below to install the location specific adapter 1 Remove the slide out plate 2 Select the appropriate AC plug adapter and in...

Страница 4: ...or Light Step 5 Apply Power Connect the power supply to the evaluation board at P2 then to an electrical outlet Ensure that the green LED D2 comes on Step 6 Demonstrate After no more than about 30 seconds generate motion in front of ZMOTIONTM Detection Module and notice the blue LED D1 to flash ON for about 2 seconds Adjust R3 Sense to change the sensitivity to motion Adjust R4 Delay to change the...

Страница 5: ...an be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2010 by Zilog Inc All rights reserved Information in this publication concerning the devices applications or technology described is intended to suggest possible uses and may be superseded ZILOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATIO...