Connectors and displays
Copyright HMS Technology
Center Ravensburg GmbH
8
USB-to-CAN
V2
-Plugin Manual, V1.2
3.1.2 Field bus connectors
If you are using a not galvanic isolated CAN interface, field bus ground (CAN
GND) and USB ground (GND) have the same potential.
Using a CAN interface with galvanic isolation, these grounds are separated.
Please be care, that in this case the grounds of the field busses (CAN1 / CAN
2 / LIN) have no galvanic isolation among each other.
For best noise immunity, the shields of the CAN cables must directly connect-
ed to ground.
Pinning of the single row female headers for field bus connections are listed
below (see also Figure 3-1).
CAN Interface 1.01.0288.xxxxx
Channel 1
Pin No.
Signal
11003
12003
22003
22043
1
CAN HS High
2
CAN HS Low
3
CAN GND
4
CAN LS High
5
CAN LS low
Channnel 2
Pin No.
Signal
1
CAN HS High
2
CAN HS Low
3
CAN GND
4
LIN
5
LIN VBat (18V max.)
Field bus galvanic isolated
Table 3-2: field bus pinning