5 Notes
5.1
CAN Busabschluss
There is no bus termination resistor for the CAN bus in the CAN interface inte-
grated. IXXAT offers a bus termination resistor as a feed through connector as
accessory (order number 1.04.0075.03000)
Figure 5-1: CAN bus termination resistor 1.04.0075.03000
5.2
LIN interface
A LIN interface is only available on model 1.01.0288.22043.
The LIN interface can be configured as LIN Master according to LIN specifica-
tion. If the CAN interface is used as a LIN-Master, a voltage of 12 V DC (volt-
age range 8 - 18 V DC) has to be connected to pin VBAT
LIN
, see Table 3-2.
Power consumption is limited by a 1 kΩ resistor.