Configuration
3.1.2 PCI bus connection
The assignment of the PCI connector is designed in accordance with the PCI
specification 2.2. The iPC-I 320/PCI II can be operated in a 5 V PCI signal envi-
ronment. The maximum PCI bus frequency with which the interface can be oper-
ated is 33 MHz.
3.1.3 Switching between loader and application mode
(S401, SW1)
By using dip switch S401 (SW1), it can be achieved that the board executes a user
defined application after reset, which has to be in flash bank 0. As default, the
IXXAT boot loader, which is in flash bank 1, is executed.
Mode S401,
(SW1)
Loader mode
(default)
OFF
Application mode
ON
3.1.4 EPLD update (S401, SW2)
Using dip switch S401 (SW2), allows to perform an EPLD update while the board
is installed in the PC.
Mode S401,
(SW2)
Programming disabled
(default)
OFF
Programming enabled
ON
3.2 CAN bus terminal
There is no bus termination resistor for the CAN bus assembled on the iPC-I
320/PCI II board. A bus terminal resistor in the form of a feed-through connector
is available as an accessory from IXXAT (order number 1.04.0075.03000).