Concrete Roof
GS Series
General Notes:
1. Top of tank junction box.
2. Eye-bolt, epoxied into hatch neck,
for retrieval chain and kellem grip.
*
3. Kellem grip.
4. Bolts, epoxied into hatch neck to
secure concrete penetration fitting.
5. Concrete penetration fitting.
*
6. Small bores drilled into hatch neck
the length of the bolts, 1/2” dia.
typical, filled with concrete
epoxy. Follow concrete epoxy
manufacture’s preparation and
installation guidelines.
7. A 3/4” dia. minimum to 1-1/4” dia
maximum hole drilled through hatch
neck for electrical cord.
8. Junction box mounted to existing or
new structure. Structure not
included.
9. 3/4” NPT electrical conduit
connection: conduit to juction box
not included.
*Not included in standard contents
Contact Ixom for
exchange.
NOT DESIGNED AS A SUBMERSIBLE
PENETRATION.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Top of Tank Junction Box
1914_10007_20200618
O&M_GS12_120V_1PH_10025_20200811 - 7