![iXBlue Gaps M5 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ixblue/gaps-m5/gaps-m5_frequently-asked-questions-manual_2098731006.webp)
In order to get the best responses from your beacons, you must always set a blanking time
based on the recurrence you have set in the Gaps. The blanking time must always be -
200ms from the recurrence of the interrogations from the system. For example, if the recur-
rence is set to 1s, then you must configure the blanking time to 0.8s. Refer to Gaps user
manual for detailed tables for different examples.
For preventive maintenance
:
In order to limit growth on the hydrophones, iXblue recommends the use of the following
anti-fouling: International - TRILUX 33
1. Sigman Coatings : blue Sigma-glide
2. They should be cleaned with isopropylic alcohol (Steps mentioned below)
3. Light abrasions with 100/120 sand paper
4. Clean with isopropylic alcohol
5. Wet the surface with aliphatic hydrocarbon solvent
6. Wait for 2 minutes to dry
7. Apply anti fouling according to the
manufacturer’s recommendations (a
thin coating)
8. Wait for 24 hours
For curative maintenance:
To clean the hydrophones; use synthetic soap and water
To remove gwth, use ro180 sandpaper and apply minimal pressure on the hydrophone
In the configuration software, press F1. In this command menu, click "diagnostic button" to
access the battery diagnosis. When the transponder is connected to the charger, the
charger LED turns green when the battery is fully charged.
The level of the battery pack when fully charged should be around 8,5V (between 8,4V and
8,6V). The battery voltage level can be requested via the following steps:
1.
Disconnect any external charger
2.
Connect the transponder to the PC through the connection box
3.
Launch the Transponder HMI interface
4.
Press the F1 key
Содержание Gaps M5