mm
A4
(Kg)
*
技 术 要 求 :
1、 尺 寸 大 小 如 图
2、 底 色 为 黑 色,正 面 为 磨 砂 面 ;
3、 颜 色 如 图 所 示.
设计
审核
批准
廖水全
2014-12-29
ARC120M
贴膜
CR-YF-TM-04B05
投影视图
图幅
单位
重量
版 本
第 1 页
共 1 页
比 例
1:1
深圳市千荣科技有限公司
CHANRONG
130
75
45
20
A/0
100
R
GORILLA
130
ø 1.6
ø 2.0
ø 3.2
ø 2.5
A
2-3.
Checking
1. Make sure the machine is properly grounded!
2. Make sure that all connections are perfect, especially grounding of the machine!
3. Check that the electrode cable connection to be perfect!
4. Make sure that the polarity is correct outputs!
5. Welding spatter can cause a fire, so make sure there are no flammable materialsthe
work area!
3.
Operation
1. Turn on the main power switch, the fan will start rotating.
2. Adjust welding parameters for welding in accordance with the value specified for
practical application.
3. Usually the welding current is formed in accordance with the electrode diameters as
follows. Make sure that it is current with reserve your unit has, otherwise do not even
try to get the job done!
The welding current reference for different electrode diameter
Electrode diameter/mm
1.6
2.0
2.5
3.2
4.0
Welding current/A
40-80
60-100
80-120
100-150
140-180
3-1
Control Panel Functions
1
Thermoprotection indicator
2 Power on indicator
3
Current adjust knob
2.
Installation
2-1.
Power Connection
1. Each machine has its own primary power cable, it must be connected to the mains
through a grounded power outlet on the right!
2. Power cable must be plugged into an appropriate power outlet!
3. Check the correct earth connection
2-2 . Accession output lines
1. Each machine has two connectors. Check the cables connected tightly to avoid
risk of burning or over heating!
2. Connect electrode cable to the negative pole , while the workpiece (earth) to the
positive!
3. Pay attention to the right polarity! Generally, there are two ways of switching the
rectifier welding machine: positive and negative connections . Posi-tives: electrode
“-”, while the work on the “+ “ to . Negatives: piece work “ - “ elect-rode while
“+” is linked to . The proper practice mode , choose as faulty switching unstable arc
and cause a lot of splashing . In this case, switch the polarity to use the machine
correctly!
4. Use a high cross section supply cable to avoid voltage drop and to keep the per
-
formance of the machine. Low input voltage will reduce the lifetime of the machine!
Control panel
“+” Electrode holder
“-” Earth Clamp
EN
EN
2
1
3
23
22
Содержание GORILLA POCKETPOWER 130
Страница 16: ...JEGYZET NOTES 31 30...