HU
EN
2.2
Layout for water cooling unit
1 Water inlet for TIG (red).
2 Water outlet for TIG (blue).
3 Intake: From here, water or coolant, antifreeze, etc. can be injected into tank.
4 Water level calibration.
5 Water inlet for MIG (red).
6 Water outlet for MIG (blue).
7 Water cooling control connector.
Further Controls Explained
Inlet (1) and outlet (2) for TIG
The two nozzles on the same side of the intake (3) are used for TIG operation and can
be connected to the nozzles on TIG welding torch. Blue corresponds to the outlet:
cold water is delivered from the tank; red corresponds to the backwater inlet: hot
water is flowed into the tank for cooling.
Note: Blue outlet and red backwater inlet must not be wrong!
Water level calibration (4)
This is a hollow trough, you can clearly observe the water volume in the tank, the
highest marking the highest water level: water volume should not exceed the high-
est water level; the lowest marking the lowest water level: when the water volume
is lower than the lowest water level, the water tank will not work properly, need to
replenish water from the intake in time.
Inlet (5) and outlet (6) for MIG
The two nozzles on the same side of Control connector (7) are used for MIG operation
and can be connected to the nozzles on the wire feeder. Blue corresponds to the
outlet: cold water is delivered from the tank; red corresponds to the backwater inlet:
hot water is flowed into the tank for cooling.
Note: Blue outlet and red backwater inlet must not be wrong!
7
Содержание 800TIG3200ACDCMW
Страница 24: ......
Страница 48: ......
Страница 49: ...CUTTING EDGE WELDING R MANUALE D UTILIZZO TIG 3200 AC DC TIG 4200 AC DC...
Страница 94: ......
Страница 98: ...www iweld hu...