HANDLING THE PRODUCT DURING TRANSPORTATION

 

In order to prevent the torch from switching on accidentally dur-
ing  transportation,  the  head  torch  should  be  removed  from  the 
Canister. This simple operation electrically decouples the battery 
from the device and prevents any current leakage to the circuit.

 

LEAVING  CAERBERUS  UNUSED  FOR  LONG  PERIODS  OF 
TIME

 

When  leaving  CAERBERUS  unused  for  long  periods  of  time  (more 
than 1 - 2 months), special attention should be paid to the level of 
charge remaining in the battery.

 

Li Ion type batteries are heavy duty batteries, however, their char-
acteristics may be subject to slight change if  left unused  for long 
periods of time. In other words, the battery capacity to store ener-
gy may deplete partially after a long period of disuse, consequently 
reducing the battery autonomy and altering discharge times slight-
ly.

 

To  contrast  this  phenomenon,  long  periods  of  disuse  should  be 
avoided  by  charging  and  discharging  the  battery  approximately 
every  two  months,  as  per  indications  in  the  “storage  procedure” 
section. In any event, the torch head should be removed from the 
Canister prior to long periods of disuse.

 

STORAGE PROCEDURE

 

The  following  procedure  is  designed  to  leave  the  battery  with  a 
residual charge of 50% - 60%. This is the optimum condition when 
leaving the product unused for long periods of time.

 

Содержание Caerberus

Страница 1: ...www iwavedesign com ...

Страница 2: ...er may cause irreparable damage to the product CAUTION Only use the product as described in the use and maintenance manual Incorrect use of the product may cause irreparable damage to the same CAUTION Do not disassemble the product for any reason The product should only be opened by persons authorised by iWave Design The opening of the product without adequate training may dam age the product and ...

Страница 3: ...h head A Illuminant torch head with Goodman handle Picture 2 Canister 2 for CAERBERUS and connect or B On switch A B C Picture 3 Detailed view of slide switch on the head C Slide switch Picture 4 Detailed view of safety valve on the Canister D Safety valve D ...

Страница 4: ...r 10Ah 5h 30min 7h 14h Canister 10Ah 4h 30min 7h 7h Canister 10Ah 4h 30min 7h 7h Burn time MAX MED MIN Canister 15Ah NA 10h 45min 20 h Canister 15Ah 6h 40min 10h 45min 10h 45min Canister 15Ah 6h 40min 10h 45min 10h 45min Charging system Automatic charger Automatic charger Automatic charger Head dimension mm 118x69x80 118x69x80 110x57x80 Cable length cm 110 110 110 Canister dimension 10Ah mm Diamet...

Страница 5: ...ies in accordance with the different canisters The LED are controlled by the electronic board with microprocessor and specific firmware able to maintain a constant light for most of the burn time When the battery has al most reached the end of its autonomy the electronics start to man age the terminal phase gradually reducing light intensity in order to extend remaining autonomy in accordance with...

Страница 6: ...orch off LOW TEMPERATURE MANAGEMENT CAERBERUS series torches are protected against low temperatures When external temperatures fall below 0 C batteries can suffer and be unable to satisfy power requests At low temperatures battery discharge autonomy may vary considerably CAERBERUS is equipped with special software called Soft Start which is able to identify low temperatures and consequently man ag...

Страница 7: ...harger into the mains socket see paragraph on battery charging Check that the switch lever on the Canister is on the on position the LED on the battery charger should be red indicating that the battery is being charged Figure 5 inserting the adapter in the Canister Figure 6 connected battery and Canister once the battery is completely charged green light on the battery charger remove the battery c...

Страница 8: ...N MODES CAERBERUS torches automatically go into MAX mode with 3 LED on when turned on To use the MED MIN modes reducing the beam of light move the slide switch on the back of the CAERBERUS torch head by moving the slide switch to the right for more than one second see picture 9 the Toggle is activated enabling alternative illumination of the single central LED or the two aside LED Each movement of...

Страница 9: ...RN CAERBERUS OFF To turn the product off use the lever switch located on the Canis ter see lever switch moving details in picture 8 HOW TO RECHARGE THE BATTERY A Li Ion battery Lithium Iron Phosphate is used for this product This type of battery is very stable with regard to temperature it is safe and completely devoid of memory effect This latter feature enables for the battery to be recharged at...

Страница 10: ...re 5 4 Plug the battery charger supplied with the product into the mains power then insert the recharge connector into the adapter screwed onto the Canister Ensure that the lever switch on the Canister is on the on position the LED on the battery charger should be red indicating that the battery is being charged In this condition the battery is being charged see picture 6 The amount of time requir...

Страница 11: ...re 11 keep the O ring seals and seats clean CAUTION Entering in water without positioning the torch head connector correctly will cause the torch to fill up with water irreparably damaging the product PRODUCT MAINTENANCE This product requires simple and basic maintenance Wash CAERBERUS in fresh water after each dive Washing with fresh water is necessary to remove any sea water residues In particul...

Страница 12: ...moved Periodically apply a layer of silicone grease on the threads and on the connector s O rings see photograph 11 taking care to keep the electrical contacts clean CAERBERUS has been designed to function over time without any problems Just a few simple maintenance operations are required to maintain the product in perfect condition during diving We recommended in any event that the manufacturer ...

Страница 13: ... their char acteristics may be subject to slight change if left unused for long periods of time In other words the battery capacity to store ener gy may deplete partially after a long period of disuse consequently reducing the battery autonomy and altering discharge times slight ly To contrast this phenomenon long periods of disuse should be avoided by charging and discharging the battery approxim...

Страница 14: ...Ah 90 minutes Canister 15Ah 110 minutes CAERBERUS S and CAVE Canister 10Ah 70 minutes Canister 15Ah 90 minutes 5 Switch the product off after the indicated discharge times 6 Dry CAERBERUS unscrew the torch head connector and re place the components in storage 7 By following this procedure the battery will contain approxi mately 50 60 of its charge and by decoupling the torch head and Canister the ...

Страница 15: ...15 www iwavedesign com ...

Отзывы: