GENERAL DESCRIPTION - 8
Environment
Operating Temperature:
0° to 40°C/32° to 104°F
Storage Temperature:
-10° to 50°C/14° to 122°F
Relative Humidity (non-condensing):
10% to 90%
FCC Registration Numbers
KF: US:BD6KF10BIWATSU1
MF: US:BD6MF10BIWATSU1
PF: US:BD6PF10BIWATSU1
BIC Registration Number
IC:577A-IWATSU1
Mounting Options
19” Rack Mount
Power Nominal Max.
IX-PWSE: 115 watts 185 watts
IX-PWSES: 115 watts 120 watts
IX-EXPWS: 115 watts 185 watts
AC Input
AC Input Voltage Tolerance:
IX-PWSE: 120
±
10% VAC
IX-PWSES: 120
±
10% VAC
IX-EXPWS: 120
±
10% VAC
Frequency Tolerance:
IX-PWSE: 60
±
3 Hz
IX-PWSES: 60
±
10%
IX-EXPWS:
60
±
3 Hz
Maximum Input Current
IX-PWSE: 3.4A
IX-PWSES: 2.2A
IX-EXPWS: 3.4A
Ringing Generator
Frequency:
20 Hz
Amplitude:
90 Vac
Maximum Simultaneous
Ringing (SLT):
20
Battery Backup
ECS IX-PWSE and
IX-EXPWS power supplies
include a battery interface.
Backup time is dependent upon
battery array, system size and
system usage.
Facility Interface Codes
Loop Start Trunks:
02LS2
Ground Start Trunks: 02GS2
DID Trunks:
02RV2-T
E&M Tie Lines:
TL31M/TL32M
OPS Lines:
0L13C
T1-SF:
04DU9-BN
T1-ESF:
04DU9-1KN
ISDN BRI:
02IS5
ISDN PRI:
04DU9-1KN
Attendant Console
Maximum Attendant Positions: 32
Loop Keys (Incoming Lines): 8
Programmable Function Keys: 16
DSS Units (Max. 4 per Attendant): 128
Programmable DSS Keys: 30
Menu Driven Software Function Keys: 8
Call Waiting Indications: 12
Alphanumeric LCD:
4 rows, 40 characters
BLF Indications: 200 x 2
Telephone Requirements
Digital Telephones
Wiring: 1 pair
Total End-to-end Distance
22 AWG Twisted Pair: 1,000 ft.
24 AWG Twisted Pair: 1,000 ft.
ICON Telephones Only:
(IX-58EXTENDER):
2,100 ft.
Platinum and IX-12KTD-3 Telephones:
(1 Star Repeater):
1,500 ft.
(2 Star Repeaters):
8,500 ft.
IP Telephones
Wiring: CAT 5 (UTP) or better
Total End-to-end Distance
CAT 5: 328 ft.
Single Line Telephones
Wiring: 1 pair
Wiring w/Message Lamp: 1 or 2 pair
Maximum Loop Resistance
(Includes SLT)
On-premise SLT:
600 ohm
Off-premise SLT:
1,200 ohm
Ringing Frequency: 20 Hz
Omegatrek IX-BS5 Base Stations
Wiring: 1 or 2 pair
Total End-to-end Distance
22 AWG Twisted Pair: 820 ft.
24 AWG Twisted Pair: 460 ft.
1 IX-BSREP Repeater: 4,450 ft.
2 IX-BSREP Repeaters: 10,150 ft.
Содержание Omegatrek PS6
Страница 1: ......
Страница 20: ...TABLE OF CONTENTS xvi IWATSU ENTERPRISE CS...
Страница 21: ...Section 1 Iwatsu Enterprise CS General Description...
Страница 22: ...GENERAL DESCRIPTION 2 IWATSU ENTERPRISE CS...
Страница 78: ...GENERAL DESCRIPTION 58 IWATSU ENTERPRISE CS...
Страница 79: ...Section 2 Iwatsu Enterprise CS Features...
Страница 80: ...SYSTEM FEATURES 60 IWATSU ENTERPRISE CS...
Страница 104: ...SYSTEM FEATURES 84 IWATSU ENTERPRISE CS...
Страница 105: ...Section 3 IP Telephone User Guide...
Страница 106: ...IP TELEPHONE USER GUIDE 86 IWATSU ENTERPRISE CS...
Страница 164: ...IP TELEPHONE USER GUIDE 144 IWATSU ENTERPRISE CS...
Страница 166: ...DIGITAL TELEPHONE USER GUIDE 146 IWATSU ENTERPRISE CS...
Страница 276: ...DIGITAL TELEPHONE USER GUIDE 256 IWATSU ENTERPRISE CS...
Страница 277: ...Section 5 Attendant Position User Guide...
Страница 278: ...ATTENDANT POSITION USER GUIDE 258 IWATSU ENTERPRISE CS...
Страница 308: ...ATTENDANT POSITION USER GUIDE 288 IWATSU ENTERPRISE CS...
Страница 309: ...Section 6 Attendant Console User Guide...
Страница 310: ...ATTENDANT CONSOLE USER GUIDE 290 IWATSU ENTERPRISE CS...
Страница 344: ...ATTENDANT CONSOLE USER GUIDE 324 IWATSU ENTERPRISE CS...
Страница 345: ...Section 7 SIP Single Line Telephone User Guide...
Страница 346: ...SIP SINGLE LINE TELEPHONE USER GUIDE 326 IWATSU ENTERPRISE CS...
Страница 369: ...Section 8 Digital Doorphone User Guide...
Страница 370: ...DIGITAL DOORPHONE USER GUIDE 350 IWATSU ENTERPRISE CS...
Страница 372: ...DIGITAL DOORPHONE USER GUIDE 352 IWATSU ENTERPRISE CS...
Страница 373: ...Section 9 Direct Inward System Access DISA User Guide...
Страница 374: ...DISA USER GUIDE 354 IWATSU ENTERPRISE CS...
Страница 378: ...DISA USER GUIDE 358 IWATSU ENTERPRISE CS...
Страница 379: ...Section 10 Hospitality Features User Guide...
Страница 380: ...HOSPITALITY FEATURES USER GUIDE 360 IWATSU ENTERPRISE CS...