6.  To refill the tank, release all air pressure by loosening the air release valve 

– Part 7 – until 

no air pressure remains inside the tank 

– the air gauge will read ‘0’. 

7.  Unscrew the lid assembly and remove. 
8.  Pour strained material into the tank. Replace lid assembly and tighten securely. 
9.  If the paint tank is accidentally tipped over or held at too great an angle, fluid will wash 

against the underside of the lid assembly and may enter the regulator and / or safety valve.  
If this happens clean immediately. 

 

Maintenance & Cleaning 

1.  Turn off the air supply to the tank. 
2.  Relieve all air pressure in the tank by loosening the air release valve 

– Part 7 – until no air 

pressure remains in the container 

– the air gauge will read ‘0’. 

3.  Unscrew  the  lid  assembly  and  remove  the  lid  assembly  from  the  paint  tank  and  empty 

remaining material. 

4.  Clean tank and parts which come into contact with paint material with a suitable solvent. 
5.  Pour solvent into tank and replace lid. 
6.  Spray until clean solvent appears. 
7.  Repeat as necessary. 

 

Trouble shooting 

Air leaking from regulator   

Air fitting is loose 

 

 

Tighten air connections 

Gauge does not operate 

 

Damaged needle on gauge 

Replace gauge 

 

 

 

 

 

Air leaking from tank 

 

Check & tighten fittings 

Material Sprays unevenly   

Strainer is blocked   

 

Clean strainer 

 

 

 

 

 

Material to thick 

 

 

Check viscosity of material 

Fluid/air leak at tank gasket 

Tighten Lid assembly 

 

Tighten lid assembly 

 

 

 

 

 

Gasket worn / damaged 

 

Replace gasket 

 

 

 

 

 

 

 

 

 

 

 

Отзывы: