4. Disassembly and Assembly
(Flange mounted Motor type)
- 37 -
• Since the magnet used in the pump is very powerful, be careful not to get your fingers
caught between the elements during the disassembly and assembly processes. Also, pay
attention to prevent metal pieces or metal powder from adhering onto the pump.
• Do not bring any electronic device that may be impacted by strong magnetic power into the
pump magnetic field.
• Prior to disassembly or assembly, close the suction valve and discharge valve.
• The piping and the pump often retain liquid. When a dangerous liquid is handled, wear
protectors (goggles, rubber gloves, etc.) when disconnecting the pipes.
b
b
Disassembly
[1] Disassemble only after thoroughly washing out the
liquid inside the pump by use of flushing piping, if
pump has drain port, remove the hex bolt (901.1) and
drain plate (122) and drain the liquid out of the casing.
Then, clean the inside of the pump.
Warning
Wear protectors (goggles, rubber gloves, etc.).
Certain liquids are dangerous. They may hurt your
eyes and skin.
[2] Remove the rear retaining hex bolt (901.3) on the
bracket (330). Then, remove the hex bolt (901.8) on
the front casing side as well as the nut (920).
[3] Screw the two attached bolts (size is M12
◊
100) from
the motor side through the tapped hole on the bracket
(330) to push out the split plate (337) so that the plate
is separated from the bracket section.
* Turn the screws alternately. If the split plate (337) has
been sufficiently driven out, hold it by hand and pull it
toward the rear. Then, rotate the plate on the base.
* During disassembly, discharge the liquid from the
casing and clean the inside of the pump.
Caution