55
O
p
e
rat
io
n
Operation programming
ANA-V programming
Select "ANA-V" or "ANA-R" in USER mode. See page 66.
Enter EXT mode.
Push the EXT key to move from manual mode to EXT mode.
*
Push the start/stop key and stop the pump when it is running. Then call up
EXT mode.
Press and hold the EXT key for one second and enter the EXT mode
selection.
Select "ANA-V" (Analogue variable).
Scroll through the EXT mode selection by the UP and DOWN keys.
Push the EXT key and enter a current value at P1.
•
A current value increases/decreases as pushing the UP/DOWN keys.
•
Press and hold either key for three seconds for quick change. Quick
change stops at 0.0 or 20.0mA. 0.0 or 20.0mA skips to 20.0 or 0.0mA
when the key is released and pushed once.
1
2
3
ON
STOP
MAN
%
MULT
ON
STOP
ON
STOP
MULT
ON
STOP
SET
4
SET
SET
ON
STOP
ON
STOP
SET
ANA. V
P1
mA
SET