- 7 -
After unpacking, check the following points to confirm that
the delivered product and its accompanying parts and
elements are exactly what you ordered.
When lifting the pump please follow the procedure
mentioned "2. Installation" of "Pump operation".
[1] Do the model and frequency indicated on the nameplate
conform to your order?
[2] Prior to the installation of the MDF-L
M
KK pump
(using SiC liner ring and mouth ring), remove the
cardboard pad inserted inside the suction port.
[3] Has the pump unit or any part of it been damaged or
bolts and nuts been loosened during delivery?
[4] The fourth numeral of the MFG. No. shows the year the
product was manufactured.
(e.g.)
×××
5
×××
"5" shows the product was manufactured in the year
1995.
If you find anything wrong, please refer to the dealer you
placed your order with.
1. Before Using Pump
2. Operating Principle
The MDF-L pump is a magnet-driven centrifugal type
pump developed for various applications.
The impeller inside the pump chamber (front casing) is
rotated by magnetic force to transfer liquid from the suction
side to the discharge side.
The MDF-L type pump features excellent corrosion
resistance, durability, and safety, and serves as a chemical
pump for various processes. Most chemicals can be
handled by the pump.
Iwaki Magnet Pump
MODEL
HEAD (m)
CAPACITY (
R
/ min)
kW
5 0
Hz rpm
MFG.No.
IWAKI EUROPE GmbH
MADE IN JAPAN
MDF - L
Year:
2P406187
: Flow of liquid
: Direction of impeller rotation
Discharge side
Suction side
Impeller
Front casing