- 8 -
3. Identification Codes
FS - 15 H T 1 - 01
a
s d f g
h
a
Series code
FS: Pump for medium & high temperature liquid and low to high-pressure applications.
s
Maximum discharge volume
FS-15 : 15 L/min.
FS-30 : 30 L/min.
FS-60 : 55 L/min.
d
Liquid temp. H : 5-180 deg.C
f
Pump connection port (discharge port/suction port)
T: Tube type connection (standard)
g
Connection between pumphead and bellows
1: Mechanical connection type
2: Weld type
h
Special specifications
No symbol : Standard
01
: Special specifications (01, 02······)
4. Specifications
Note 1. The maximum discharge volume value is based on pure water at room temperature.
Note 2. Supply air pressure must be limited to 0.147-0.294MPa to get the max. stroke speed. Max. stroke speed must
be 180 spm or less if supply air pressure exceeds 0.295MPa and below 0.490MPa.
Note 3. The self-priming value is based on the maximum stroke speed with pure water at room temperature.
Item
FS-15HT1/T2
FS-30HT1/T2
FS-60HT1/T2
General
Specification
Max. discharge volume (Note 1)
15 L/min
30 L/min
55 L/min
Max. stroke speed (Note 2)
240 spm
220 spm
200 spm
Self-priming ability (Note 3)
1 m
Liquid temp. range (deg.C)
5-50
51-100
101-180
5-50
51-100
101-180
5-50
51-100
101-180
Supply air pressure range (MPa)
0.147-
0.490
0.147-
0.294
0.147-
0.196
0.147-
0.490
0.147-
0.294
0.147-
0.196
0.147-
0.490
0.147-
0.294
0.147-
0.196
Liquid-contacting material
PFA, PTFE
Pump connection port
PFA 1/2" tube
(O.D. 12.7
×
I.D. 9.52 mm)
PFA tube
(O.D. 19
×
I.D. 16 mm)
PFA tube
(O.D. 25
×
I.D. 22 mm)
Supply air connection port
Rc 1/4"
Rc 1/4"
Rc 3/8"
Max. air consumption
(at max. discharge volume,
max. supply air pressure)
200
Nl/min
160
Nl/min
110
Nl/min
370
Nl/min
280
Nl/min
170
Nl/min
670
Nl/min
440
Nl/min
300
Nl/min
Ambient temp.
0~40 deg.C
Driving method
External forced switching of driving air
Proximity
switch
arrangement
Type
High-frequency type proximity switch
Output type
NPN DC open/close output
Source voltage
DC10V~DC30V
2 m
2 m