Open the package and check that the product conforms to your order. If 
any problem or inconsistency is found, immediately contact your distribu-
tor.

a. Check if the delivery is correct.

Check the nameplate to see if the 
information such as model codes, 
discharge capacity and discharge 
pressure are as ordered.

b. Check if the delivery is damaged or deformed.

Check for transit damage and loose bolts.

Order confirmation

Содержание APN-110-D3

Страница 1: ...td TEL 86 7503866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pum...

Страница 2: ...ncy is found immediately contact your distribu tor a Check if the delivery is correct Check the nameplate to see if the information such as model codes discharge capacity and discharge pressure are as...

Страница 3: ...p structure Operating principle 12 Part names 13 Identification codes 14 Installation 15 Pump mounting 15 Pipework 16 Tube connection 16 Wiring 17 Power External signal cables 17 Before work 17 Rated...

Страница 4: ...ction 23 Daily inspection 23 Wear part replacement 24 Wear part list 24 Before service 24 Diaphragm replacement 25 Valve replacement 26 Specification Outer dimension 27 Specification 27 Outer dimensio...

Страница 5: ...anies each precaution suggesting the use of Caution Pro hibited actions or specific Requirements I ndicates mishandling could lead to personal injury or property damage CAUTION Caution marks Prohibiti...

Страница 6: ...turer s responsibility for any failure or injury resulting from alternations to the pump Use specified power only Do not apply power other than that specified on the nameplate Otherwise failure or fir...

Страница 7: ...pump In a flammable atmosphere In a dusty humid environment Where operating or storage temperature can fall below 5 C or 0 C or exceed 40 C In direct sunlight or wind rain Spill precautions Ensure pr...

Страница 8: ...ond the extent of the instructions Do not use a damaged pump Use of a damaged pump could lead to an electric shock or death Disposal of a used pump Dispose of any used or damaged pump in accordance wi...

Страница 9: ...mp Otherwise the pump performance may reduce or the lives of the valve and diaphragm remarkably shorten Do not install the pump in a corrosive or flamma ble gas atmosphere Keep good ventilation in a w...

Страница 10: ...nt must be below the pump position Or siphon action back flow may result Use care handling the pump Do not drop An impact may affect pump performance Do not use a pump that has been damaged to avoid t...

Страница 11: ...sk of burning Pump and pipe surface tempera tures rise high along with liquid temperature Do not touch the pump or pipe surface directly during operation or right after operation Always use a suction...

Страница 12: ...type air pump with a brushless DC motor The rotary motion of the motor is converted through a connecting rod to the reciprocation of the diaphragm in the pump chamber where gas is transferred from the...

Страница 13: ...mes Outlet Base Always fix with screws Specification label Use the pump accord ing to the specifica tions on the label Pump head Not capable of liquid transfer Air transfer purpose only Inlet Pump bod...

Страница 14: ...d e f a Pump size b Pump head K In line type L Parallel type c Diaphragm Valve materials N NBR E EPDM V FKM d Pump connection No code 8 tube connection X Rc1 4 female thread connection JIS taper pipe...

Страница 15: ...n off power to stop the pump and related devices before service is performed If you notice any abnormal or dangerous conditions suspend operation immediately and inspect solve problems Do not operate...

Страница 16: ...he pump inlet outlet for the prevention of gas ingress leak or other failure Do not have tubing bent or pressed Otherwise the tube end may break Connect tubes into the inlet and outlet Push the tubes...

Страница 17: ...ltage See the spec label When an external fuse is used and it has blown always solve the root cause of blowout Be sure to unplug the power cable before investigation If the fuse blows frequently the s...

Страница 18: ...stem is free from the inductive noise at start up Noise accompanies the high speed switching of the drive circuit Check it does not affect peripheral devices If a power source is shared with the induc...

Страница 19: ...e connected the other way around pumping process is inverted c Check that every tube connection is secured d Check that electrical wiring is properly done without the possibility of short circuit and...

Страница 20: ...ine pressure at the time of power recovery After starting check a pressure gauge to see if suction and dis charge line pressure are correct and an air flow meter to see if the specified air flow is ob...

Страница 21: ...nd operation im mediately and check the following points If the following measures do not help remove problems contact your nearest distributor States Possible causes Solutions The pump does not run P...

Страница 22: ...e pressure is too low Wrong tubing or poor connection Check and fix tubing Pump head mounting screws are loose Tighten the screws Diaphragm fixing screw is loose Tighten the screw Diaphragm is broken...

Страница 23: ...When wear parts come to the life limit replace them by new ones Contact your distributor for detail No States Points to be checked 1 Pumping If the specified power voltage starting current are observe...

Страница 24: ...es with new ones Application Estimated life Valve Diaphragm All APN 110 models 8000hr 8000hr Wear part duration varies with the pressure temperature and characteristics of gas The estimated life above...

Страница 25: ...plate onto the under retainer plate Secure the retainer plate and dia phragm Apply the LOCTITE 222 to the dia phragm fixing screw and tighten it by 1 96N m Push down the diaphragm until it bottoms out...

Страница 26: ...Check the air flows from the inlet to the outlet Push down the diaphragm until it bottoms out Secure the pump head unit onto the bracket with the fixing screws by 1 96N m NOTE Do not loosen the bracke...

Страница 27: ...serve the maximum allowable discharge pressure of 0 05MPa Allowable gas temperature range is 0 40 C Allowable ambient temper range is 5 40 C Both the inlet and outlet of the pump are Rc1 4 female thre...

Страница 28: ...0 12 8 129 2 Rc1 4 or 2 G1 4 134 29 91 74 Tube connection 101 3 87 98 74 65 61 32 47 99 34 66 21 33 8 00 0 02 0 04 0 06 0 08 0 10 0 2 10 15 Discharge pressure 0MPa Vacuum 101 3kPa abs Vacuum 87 98kPa...

Страница 29: ...ty No Part names Q ty 1 Pump head 1 18 Under retainer plate 1 2 Valve 1 19 Connecting rod 1 3 Valve seat 1 20 Bracket 1 4 Diaphragm 1 40 Motor 1 5 Retainer plate 1 60 Set screw 2 8 Eccentric shaft 1...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...td TEL 86 7503866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pum...

Отзывы: