Pump characteristics, features and part names are described
in this section.
Introduction
Pump structure & Operating principle
The APN-110-D3 is a diaphragm type air pump with a brushless DC motor.
The rotary motion of the motor is converted through a connecting rod to the
reciprocation of the diaphragm in the pump chamber, where gas is transferred
from the inlet to outlet.
Outline
Suction process
Outlet
Inlet
Connecting rod
Diaphragm
Discharge process
Outlet
Inlet
: Diaphragm reciprocation
: Gas flow