Service menu
AirModule –6 720 813 268(2014/10)
45
Type of building
When adjustment is activated, the type of building can be used to set the
adjustment (equalisation) of variations in the outside temperature. The
outside temperature adjustment takes into consideration the building
type's thermal inertia. By setting the type of building you can thereby
adjust the control to the characteristics of the building.
Fig. 39 Example of adjusted outside temperature
[1]
current outside temperature
[2]
adjusted outside temperature
This greatly simplified example shows how the adjusted outside
temperature follows the current outside temperature, but does not
reach its extreme values.
Minimal outside temperature °C
Aten
– 2
Köpenhamn
– 13
Paris
– 10
Berlin
– 15
Lissabon
0
Prag
– 16
Bryssel
– 10
London
– 1
Rom
– 1
Budapest
– 12
Madrid
– 4
Sevastopol
– 12
Bukarest
– 20
Marseille
– 6
Stockholm
– 19
Hamburg
– 12
Moskva
– 30
Valencia
– 1
Helsingfors
– 24
Neapel
– 2
Wien
– 15
Istanbul
– 4
Nice
0
Zürich
– 16
Table 29 Minimal outside temperature
In the standard settings, the outside temperature
influence on the control is delayed by three hours.
▶ The development of the outside temperature over
the past two days is displayed in the following menu:
Info
>
Outside temp.
>
Outside temp. curve
6720 645 480-30.1O
2
1
0°C
20°C
0 h
12 h
24 h