General

Electric boiler IVT 290 A/W can be used free-standing or together with air/water heat pump IVT 
Optima 600-1100, which forms a complete solution for both heating and hot water. The hot water 
heater is in the electric boiler and is stainless steel. The hot water heater has a protective anode that 
is maintenance free and is suitable for all types of water.

The electric boiler is installed indoors and the heat pump is installed outdoors. The heat pump 
collects energy from outside air. The energy is transferred via heated water to the electric boiler 
for further transfer out into the house’s heating system (radiators and/or underfl oor coils) and for 
heating the hot water.

The Rego 800 control unit, in the electric boiler, controls and monitors the whole installation. It 
contains a control panel with graphic presentation. Most settings needed to give the installation the 
best possible function in your house, are made via the control panel by the installer (or are preset in 
the factory). In addition, you can affect operation in different ways, for example, by increasing/de-
creasing the heating, obtaining extra hot water etc., using the control panel. 

There are a number of sensors in the system to assist adjusting heating and hot water production for 
different demands. These give the control unit information about for instance the current outdoor 
temperature and hot water temperature.

The unit can be supplied with a power guard (option). The task of the power guard is to temporarily 
disconnect the electrical additional heat when using other power demanding appliances so that the 
main fuse does not blow.

Control unit with 
control panel

Electric boiler 290 A/W

(placed indoors)

Optima heat pump

(placed outdoors)

General

Power guard, option

(placed indoors)

Содержание 290 A/W

Страница 1: ...IVT 290 A W Electric boiler User Guide Art no 12322 Version 1 0...

Страница 2: ...t at a low level while you are away on holiday IVT is the leading heat pump manufacturer in the Nordic Countries More than every second heat pump comes from IVT We have worked with solutions to reduce...

Страница 3: ...er works 6 Component parts 7 Maintenance 8 Check the pressure gauge 8 Clean the discharge water vessel 8 Check the safety valves 8 What to do if a fault occurs 9 Protective anode 9 Overheat protection...

Страница 4: ...panel This guide contains a description of 290 A W what it consists of main tenance etc The control unit and settings for Optima with 290 A W are described in the Optima guide It is important as the...

Страница 5: ...contains a control panel with graphic presentation Most settings needed to give the installation the best possible function in your house are made via the control panel by the installer or are preset...

Страница 6: ...ter shell and heats up the hot water until the hot water requirement is met While it is doing so no heat is produced The switch between heating and hot water production occurs automati cally at a cert...

Страница 7: ...eat to the radiator system The temperature of the radiator system is regulated via the flow line sensor T1 and the heating settings in the control unit Extra hot water and hot water peaks The electric...

Страница 8: ...tima are made here In addition there are 3 way valves mixing valves etc Hot water heater The water heater is double shelled and stainless steel It holds 160 litres of water Control panel with graphic...

Страница 9: ...n area Clean the discharge water vessel Twice a year Wash the discharge water vessel with warm water and anti bacterial cleaning agent to remove dirt and algae Rinse and check that the water runs off...

Страница 10: ...eat protection is on the front of the electric box This is a protection device that should normally not trip If however it does trip reset it by pressing in the button firmly If the overheat protectio...

Страница 11: ...5 60 1 170 65 0 980 70 0 824 75 0 696 80 0 590 85 0 503 90 0 430 IVT 290 A W Output electric element kW 9 13 5 Output circulation pump kW 0 2 Electrical supply 400V 3N 50Hz Max power consumption kW 9...

Страница 12: ...IVT Industrier AB Sweden www ivt se mailbox ivt se...

Отзывы: