Ivoclar Vivadent SR Ivocap Скачать руководство пользователя страница 3

3

Index

Page

Views of the Furnace, List of Parts

4

1.

Introduction / Signs and Symbols

5

1.1

Introduction

1.2

Signs and symbols

1.3

Notes regarding the Operating Instructions

2.

Safety First

6

2.1

Indications

3.

Product Description

7

3.1

Components 

3.2

Hazardous areas and safety equipment

3.3

Functional description

3.4

Accessories

4.

Installation

8

4.1

Unpacking and checking the contents

4.2

Selecting the location

5.

Operation

9

5.1

Operating elements at the pressure apparatus

5.2

Operating elements at the clamping frame

6.

Procedure

10

6.1

Practical use

7.

Maintenance, Cleaning, and Diagnosis

11

7.1

Monitoring and maintenance

7.2

Cleaning

7.3

Changing the Compression spring

8.

What if…?

12

8.1

Error messages

8.2

Repairs

9.

Product Specifications

13

9.1

Delivery form 

9.2

Technical data

9.3

Acceptable operating conditions

9.4

Acceptable transportation and storage conditions

Содержание SR Ivocap

Страница 1: ...Operating Instructions SR Ivocap Equipment System...

Страница 2: ...2...

Страница 3: ...lation 8 4 1 Unpacking and checking the contents 4 2 Selecting the location 5 Operation 9 5 1 Operating elements at the pressure apparatus 5 2 Operating elements at the clamping frame 6 Procedure 10 6...

Страница 4: ...eter A3 Extrusion piston A4 Vise shank A5 Safety loop B Clamping frame JS3 B2 Thrust collar with lever B3 Pressing plate C Flask C1 Flask half M C2 Flask half W C3 Flask lid C4 Injection funnel D Caps...

Страница 5: ...rmation Contraindication 1 3 Notes regarding the Operating Instructions These Operating Instructions must be read prior to working with the SR Ivocap System Equipment concerned SR Ivocap System Target...

Страница 6: ...y risk resulting from failure to observe these Instructions Further instructions to assure proper use of the system The instructions regulations and notes in these Operating Instructions must be obser...

Страница 7: ...as been especially developed to compensate curing shrinkage Controlled polymerization allows shrinkage of the material during polymerization to be compensated by inflowing material The SR Ivocap injec...

Страница 8: ...poses 4 2 Selecting the location The diagram below depicts one possible installation Important information For safety reasons the installation of the pressure power and water connections may only be c...

Страница 9: ...sed horizontal position 5 2 Operating elements on the clamping frame Thrust collar with lever B2 Operation 1 Thrust collar with lever closed push to the right until it stops 2 Thrust collar with lever...

Страница 10: ...oling in a cold water bath at least 30 minutes the injection pressure must be maintained for at least 20 minutes thereof 3 2 1 Compressed air 6 bar Water level Pressure apparatus Capsule Flask Mark fo...

Страница 11: ...air connection before maintenance and cleaning 7 1 Monitoring and maintenance The time for these maintenance procedures depends on the frequency of use and work ing habits of the users For that reaso...

Страница 12: ...tes for users Flask margins are not clean plaster residue on the injection funnel The model should be trimmed prior to investment Clamping frame is not correctly positioned i e in the centre of the pr...

Страница 13: ...Acceptable operating conditions Acceptable humidity range Maximum relative humidity at 31 C 87 F gradually decreasing to 50 at 40 C 104 F condensation excluded Acceptable ambient pressure The unit is...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...627 33 99 Fax 57 1 633 16 63 www ivoclarvivadent com Ivoclar Vivadent SAS B P 118 F 74410 Saint Jorioz France Tel 33 450 88 64 00 Fax 33 450 68 91 52 www ivoclarvivadent fr Ivoclar Vivadent GmbH Dr Ad...

Отзывы: