5.5  Settings / configuration and information 

By pressing the "Settings" key (78), the following menu is displayed:

The left key (<) can be used to navigate through the information
menu. The right key (>) is used to navigate through the settings and
auxiliary programs. These displays can be aborted by pressing the
Program key or ESC key.

5.5.1 Settings / Configuration

Information Settings

Settings 

Contrast 

Temperature mode 

User calibration
value 

Volume 

Beeper tune 

Time 

Date 

Display Short 

description 

The contrast can be
set by means of the 
+ or – keys

The + and – keys can
be used to switch
from °C to °F

This program is 
suitable to conduct
the temperature 
calibration by means
of the Temperature
Checking Set Type 2.
The furnace head
opens automatically
if the Enter key is 
pressed. Place the
test into the firing
chamber and start
the program by
means of the START
key. 

The desired volume
can be set by means
of the + or – keys

The tune can be set
by means of the + or
– keys

The time can be 
entered by using the
numeric keys

The date can be 
selected by using the
numeric keys

Settings 

Write protection 

”Ivoclar Vivadent
optimized 
temperature control
function“

Pre-drying 

Vacuum test 
program

Heating muffle test
program  

Key test  

Cleaning program

Dehumidification
program

Selection of factory
settings 

Display Short 

description 

The + and – keys can
be used to switch on
the write protection.
The function applies
to all programs and
cannot be individually
set.   
Only after entry of
the user code.

Only after entry of
the STD code.

The + and – keys can
be used to switch on
the pre-drying func-
tion. The function
applies to all pro-
grams and cannot be
individually set. 

Allows to check the
vacuum quality of the
system 

Allows to check the
heating muffle. The
result is shown in
graphical form after
the end of the 
program 

Allows to check the
keypad

The program is used
to clean the heating
muffle and the 
insulation materials
by a heat process.

Permits the 
dehumidification of
the furnace

With this setting, all
values and para-
meters can be reset
to the factory 
settings. 

Attention

All individual pro-
grams which have
been created and
saved will be deleted
with this function.

Содержание Programat P300

Страница 1: ...Operating Instructions Programat P300...

Страница 2: ...2...

Страница 3: ...Explanation of the key functions 5 3 Program structure 5 4 Adjustable parameters and possible value ranges 5 5 Settings test programs and information 5 6 Explanation of the symbols on the display 5 7...

Страница 4: ...hose connection 23 Rubber feet 24 Protective cover vacuum 25 Furnace head housing 26 Thermocouple plug 27 Plug fuse 28 Heater plug 29 Heater plug socket 30 Thermocouple plug socket 32 Leaf spring 33 A...

Страница 5: ...5 40 25 34 6 10 35 23 47 33 1 7 5 2 3 4 8 9...

Страница 6: ...6 37 39 36 11 38 25 19 13 12 49 26 30 29 50 51 27 28 11 32 43 12 13 15 19 46 21 17 18 16...

Страница 7: ...y temperature 82 Closing time 83 Temperature increase 84 Holding temperature 85 Holding time 86 Vacuum on 87 Vacuum off 88 Long term cooling 90 Open furnace head 91 Close furnace head 92 Numeric keys...

Страница 8: ...joy working with the P300 1 2 Introduction The signs and symbols in these Operating Instructions facilitate the finding of important points and have the following meanings Risks and dangers Important...

Страница 9: ...must be observed The furnace must be operated under the indicated environmental and operating conditions Chapter 9 The Programat P300 must be properly maintained 2 1 1 Risks and dangers The furnace he...

Страница 10: ...e skin grease contamination as the parts will be prematurely dama ged 2 1 12 Risk of crushing and burn hazard Never reach under the furnace head with the hand or other parts of the body during operati...

Страница 11: ...nditions over an extended period of time Use only original spare parts The temperature range for faultless operation is 5 C to 40 C 41 F to 104 F If the furnace has been stored at very low temperature...

Страница 12: ...uum may be created with a vacuum pump The firing process is controlled with the corresponding electronic con trols and a software Moreover the set and actual temperatures are continuously compared 3 4...

Страница 13: ...ly use the two corresponding inserts Fold the side flaps 2 and combine the two packaging parts by means of the transportation flaps The packaging may be disposed with the regular household refuse 4 2...

Страница 14: ...e 5 on the firing plate holder 48 Secure the cooling tray 34 with the two screws 35 including the silicone rest 47 Place the cooling tray 34 on the frame plate 7 Make sure that the cooling tray 34 is...

Страница 15: ...ace head mounting 43 Ensure that the furnace head mounting mark 41 is aligned with the furnace base mounting mark 42 Make sure that the firing plate 5 is not damaged by mounting the furnace head Step...

Страница 16: ...itional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 16 with the power socket 17 of the furn...

Страница 17: ...d 16 with the wall socket 2 Put the On Off switch 11 at the rear of the furnace on position I The furnace will now automatically conduct a self test The performance of all furnace components is automa...

Страница 18: ...n menu The right key can be used to navigate between the settings and auxiliary programs Cursor keys 79 80 The current cursor position is indicated by means of a fix non blinking frame around the valu...

Страница 19: ...uration and information 5 4 Adjustable parameters and possible value ranges Symbol Parameter Value range Value range P Program number P 1 100 B Stand by temperature 100 700 C 212 1292 F S Closing time...

Страница 20: ...ntered by using the numeric keys The date can be selected by using the numeric keys Settings Write protection Ivoclar Vivadent optimized temperature control function Pre drying Vacuum test program Hea...

Страница 21: ...reset to 0 Only after entry of the user code Settings Serial number Software version Furnace head firing hours Operating hours furnace Operating hours vacuum pump Latest start of calibration program...

Страница 22: ...ox 10 seconds with the beeper signal set by the user If the STOP key is not pressed during this time the beeper sounds again after 5 minutes for a period of 5 minutes Subsequently there will be no fur...

Страница 23: ...priate symbol first or second stage Two stage program stage 1 is shown stage 2 is shown If the cursor is positioned on the one stage symbol and the symbol is switched to the two stage symbol by pressi...

Страница 24: ...ttom line until the next value is entered and successfully confirmed or the process is aborted with ESC The old valid value reappears Please refer to the parameter details for the value range 6 4 2 Pr...

Страница 25: ...on the surface of the insulation are harmless and do not influence the function of the furnace in a negative fashion weekly Thermocouple 4 Check if the thermocouple is straight and in the right place...

Страница 26: ...s the ENTER key The following is displayed c Insert silver wire into the Ivoclar Vivadent sample holder d Place the sample holder with the silver strip in the centre of the firing plate 6 e Press STAR...

Страница 27: ...local Ivoclar Vivadent Service Center 13 System Heating muffle very old 23 The heating muffle is very old It is recommended to replace it After the error message has been acknowledged a firing program...

Страница 28: ...ng program from the The program could not be continued since the USB memory stick is no longer present memory stick in progress memory stick no longer present 40 System Prolonged power failure 704 An...

Страница 29: ...ure 69 System Reading calculating the 1204 no Error while measuring the furnace control temperature furnace control temperature 70 System Reading caluclating the 1205 Error while measuring the resista...

Страница 30: ...and on again If it still does not work properly contact your local Ivoclar Vivadent Service Center Vacuum pump does not start working Is the vacuum pump fuse defective Check fuse and replace if necess...

Страница 31: ...e Depth 368 mm width 303 mm 398 mm with Cooling tray Height 320 mm Usable size of the firing chamber Diameter 80 mm Height 48 mm Max firing temperature 1200 C 2192 F Weight Furnace base 12 3 kg Furnac...

Страница 32: ...local Service Center Important information The current program table is also available at www ivoclarvivadent com The program tables can be downloaded from the Internet as PDF files Please make sure t...

Страница 33: ...66 77 80 www ivoclarvivadent it Ivoclar Vivadent S A de C V Av Mazatl n No 61 Piso 2 Col Condesa 06170 M xico D F Mexico Tel 52 55 5062 1000 Fax 52 55 5062 1029 www ivoclarvivadent com mx Ivoclar Viv...

Отзывы: