Views of the Furnace, List of Parts

4

1.

Introduction / Signs and Symbols

8

1.1

Preface

1.2

Introduction

1.3

Notes regarding the Operating Instructions

1.4

Notes on the different voltage versions

2.

Safety First

9

2.1

Indications

2.2

Health and safety instructions

3.

Product Description

12

3.1

Components

3.2

Hazardous areas and safety equipment

3.3

Functional description

3.4

Accessories

4.

Installation and Initial Start-Up

13

4.1

Unpacking and checking the contents

4.2

Selecting the location

4.3

Assembly

4.4

Dismounting the furnace head

4.5

Initial start-up

4.6

Dehumidification

5.

Operation and Configuration

18

5.1

Introduction to the operation

5.2

Explanation of the key functions

5.3

Program structure

5.4

Adjustable parameters and possible value ranges

5.5

Settings / test programs and information

5.6

Explanation of the symbols on the display

5.7

Explanation of the beeper signals

6.

Practical Use

23

6.1

Switching on/off

6.2

Firing using an Ivoclar Vivadent program

6.3

Firing using an individual program

6.4

Other options and special features of the furnace

7.

Maintenance, Cleaning and Diagnosis

25

7.1

Monitoring and maintenance

7.2

Cleaning

7.3

Special programs

7.4

Temperature calibration

7.5

Service note

7.6

Stand-by

8.

What if ...

27

8.1

Error messages

8.2

Technical malfunctions

8.3

Repair

9.

Product Specifications

30

9.1

Delivery form

9.2

Technical data

9.3

Acceptable operating conditions

9.4

Acceptable transportation and storage conditions

10. Appendix

31

10.1 Program table
10.2 Menue structure
10.3 Firing curves

Table of Contents

Содержание Programat P300/G2

Страница 1: ...Operating Instructions Programat P300 G2 s Valid as of software Version 5 0...

Страница 2: ...2...

Страница 3: ...ey functions 5 3 Program structure 5 4 Adjustable parameters and possible value ranges 5 5 Settings test programs and information 5 6 Explanation of the symbols on the display 5 7 Explanation of the b...

Страница 4: ...use 28 Heater plug 29 Heater plug socket 30 Thermocouple plug socket 32 Leaf spring 33 Air vents base 34 Cooling tray 35 Screw for cooling tray 36 Hood 37 Knurled screw for hood 38 Air vents furnace h...

Страница 5: ...5 40 25 34 6 10 35 23 47 33 1 7 5 2 3 4 8 9...

Страница 6: ...6 49 26 30 29 50 51 27 28 11 32 43 37 39 36 11 38 25 19 53 13 12 12 13 15 19 46 21 17 18 16...

Страница 7: ...losing time 83 Temperature increase 84 Holding temperature 85 Holding time 86 Vacuum on 87 Vacuum off 88 Long term cooling 89 Power saving key 90 Open furnace head 91 Close furnace head 92 Numeric key...

Страница 8: ...cation Burn hazard Risk of crushing The Operating Instructions must be read 1 3 Notes regarding the Operating Instructions Furnace concerned Programat P300 G2 Target group Dental technologists These O...

Страница 9: ...e must be observed The furnace must be operated under the indicated environmental and operating conditions Chapter 9 The Programat P300 G2 must be properly maintained 2 1 1 Risks and dangers The furna...

Страница 10: ...l be prematurely damaged 2 1 11 Risk of crushing and burn hazard Never reach under the furnace head with the hand or other parts of the body during operation since there is a risk of crushing and a bu...

Страница 11: ...original spare parts The temperature range for faultless operation is 5 C to 40 C 41 F to 104 F If the furnace has been stored at very low temperatures or high atmospheric humidity the head has to be...

Страница 12: ...hat a vacuum may be created with a vacuum pump The firing process is controlled with the corresponding electronic con trols and a software Moreover the set and actual temperatures are continuously com...

Страница 13: ...mply use the corresponding inserts Fold the side flaps 2 and combine the two packaging parts by means of the transportation flaps The packaging may be disposed of with the regular household refuse 4 2...

Страница 14: ...5 on the firing plate holder 48 Secure the cooling tray 34 with the two screws 35 including the silicone washer 47 Place the cooling tray 34 on the frame plate 7 Make sure that the cooling tray 34 is...

Страница 15: ...ace head mounting 43 Ensure that the furnace head mounting mark 41 is aligned with the furnace base mounting mark 42 Make sure that the firing plate 5 is not damaged by mounting the furnace head Step...

Страница 16: ...ng additional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 16 with the power socket 17 of th...

Страница 17: ...ion I The furnace will now automatically conduct a self test The performance of all furnace components is automatically checked The display shows the following indications during the self test 1 Statu...

Страница 18: ...ix non blinking frame around the value Enter keys 76 77 92 The values can be entered by using the keys or the numeric keys Each value entered by means of the or key will be immediately accepted as lon...

Страница 19: ...ne or two stage program by using the or key 5 4 Adjustable parameters and possible value ranges Symbol Parameter Value range Value range P Program number P 1 300 B Stand by temperature 100 700 C 212 1...

Страница 20: ...ntered by using the numeric keys The date can be selected by using the numeric keys Settings Write protection Ivoclar Vivadent optimized temperature control function Power saving mode Service interval...

Страница 21: ...user code The firing hour count can be reset to 0 Only after entry of the user code The operating hour count of the vacuum pump can be reset to 0 Only after entry of the user code Settings Serial num...

Страница 22: ...lf test is completed To inform the user that the automatic self test has been successfully completed the selected melody is played 2 Furnace head open and temperature below 550 C 1022 F To inform the...

Страница 23: ...being displayed Special variant Conducting a one stage program in which only part of the holding time is fired with a vacuum requirement holding temperature 1 holding temperature 2 6 1 3 Operating ind...

Страница 24: ...of the furnace head If the cursor is on the spot in the parameter list shown in the figure you can toggle between the following functions by using the or key Thermo Shock Protection Pre drying no func...

Страница 25: ...s and do not influence the function of the furnace in a negative fashion weekly monthly weekly When Thermocouple 4 Check if the thermocouple is straight and in the right place Opening mechanism Check...

Страница 26: ...s menu by pressing the Information Settings key Subsequently press and hold the right cursor key 79 until the following display appears To select the calibration pro gram press the ENTER key The follo...

Страница 27: ...to start a firing program firing program 27 no Furnace head cannot The furnace head cannot be moved to the final position It might be blocked by an external mechanical be initialized source If not co...

Страница 28: ...e following error messages is being displayed 25 29 43 44 45 46 47 48 54 56 103 107 143 144 145 146 147 148 700 701 703 704 705 706 707 1010 1011 1012 1013 1014 1015 1016 1024 1025 1026 1028 1143 1144...

Страница 29: ...program still running Wait until the program is complete Switch furnace off and on again If it still does not work properly contact your local Ivoclar Vivadent Service Centre Vacuum pump does not sta...

Страница 30: ...he closed furnace Depth 430 mm width 305 mm 410 mm with Cooling tray Height 320 mm Usable size of the firing chamber Diameter 80 mm Height 48 mm Max firing temperature 1200 C 2192 F Weight Furnace bas...

Страница 31: ...rvice Centre Important information The current program table is also available at www ivoclarvivadent com downloadcenter The program tables can be downloaded from the internet as PDF files Please make...

Страница 32: ...32 10 2 Menu structure 10 2 1 Possibilities of the program selection...

Страница 33: ...33 10 2 2 Information Settings...

Страница 34: ...34 10 3 Firing curves 10 3 1 Vacuum during both stages 10 3 2 Vacuum during long term cooling 10 3 3 Pre drying 10 3 4 Controlled long term cooling...

Страница 35: ......

Страница 36: ...7 www ivoclarvivadent com Ivoclar Vivadent S A de C V Av Mazatl n No 61 Piso 2 Col Condesa 06170 M xico D F Mexico Tel 52 55 5062 1000 Fax 52 55 5062 1029 www ivoclarvivadent com mx Ivoclar Vivadent L...

Отзывы: