![iVex Indusvision IVEX-FZ Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ivex-indusvision/ivex-fz/ivex-fz_user-manual_2097416011.webp)
11
5. Installation
5-6. Basic Installation
1. (A)
Please check the status thread of the nut if there is dusts or regular condition for hex.
Stainless steel bolt or wrench bolt (M8x1.25Px20L) and fix it with washer/spring-washer to keep
locking the bolts on the product.
2.
According to the environment, it can be changed brackets
(to be Wall Mount Type or Pedestal Type), (refer to the “Chapter.8 Dimension”)
3. (B)
Check the thread of the sealing fittings if there is dust or good status for using.
4. (C)
Connect a nipple with thread of cable entry and tighten flexible cable in the sealing fitting.
In here, all cables have to come out though sealing fitting and all of sealing fitting, cable grand,
and flexible cable must be certified the explosion proof standards.
[C]
[B]
[A]
NPT 3/4“
-14 Cable grand
Ex-proof Sealing fitting
Filter
Finishing material
Cable
(M8 x 1.25P x 20L) x 4 set
NPT 3/4”
-14
Nipple(including)
NPT 3/4“
-14
Sealing fitting
(Non-including)
Ex-proof
Flexible cable
(Non-including)