23
General status
0
System off
249
EV mode
–
accelerator fully depressed
250
EV mode
251
HEV mode
252
SAVE mode
253
CHG mode
EDS-150 faults
60
Current sensor failure
61
Over current fault
62
Phase U Fault
63
Phase V Fault
64
Phase W Fault
65
Master Inverter Fault
66
Encoder Error
67
DC Over-voltage
68
DC Under-voltage, pre-charge failure
69
DC Link error
70
DC Link disconnected
75
12V power supply too low (<10,5V)
79
Unexpected emergency shut-down
Temperature
71
MCU board temperature error (>125 C)
72
IGBT temperature error (>85 C)
73
Motor temperature error (>150 C)
74
IGBT temperature sensor failure
130
IGBT Temperature warning (>70 C)
131
Motor power limited (>75 C)
132
IGBT Temperature critical (>75 C)
133
Motor temperature critical (>85 C)
134
IGBT over-heat lock (> 80 C)
135
Motor over-heat lock (> 90 C)
136
Low battery temperature (< -15 C)
137
Low EDS temperature (< -25 C)