Before going to
Mode 6
please make sure that the “Known load
weight” is ready to be lifted.
-
The loaded forks must be on the ground.
(
No hydraulic pressure in the lifting hydraulic circuit
)
- Press the
“M”
button to advance to
Mode 6
and immediately lift
the “Known load weight” just above the ground.
Note:
Activate the lift control valve as you would do during the normal
lifting operation. Do not attempt to lift the empty forks slowly.
- LED display will go blank and within few seconds LED display
will show the value of calibrated “Known load weight of 4000”
Lower the load to the ground.
System will go automatically into operational mode.
System is ready to be used.
Mode digit will display number
8.
Note:
If system is set up for overload alert the
Mode 7
will be shown automatically. Follow instruction for
overload warning alert value input.
Weighing calibration function is completed
Lower loaded forks to the ground.
Integrated Visual Data Technology Inc., 3439 Whilabout Terrace, Oakville, Ontario, Canada L6L 0A7